APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This 3 phase PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU via IEC 309 3P+N+PE plug with a 1.8m (16 ft) cord while power comes out at 230 volts through (36) C13 and (6) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
Rack PDU 2G, Metered, ZeroU, 14.4Kw, 208V, (36) C13 & (12) C19
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).InfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.High online efficiencyReduces utlility costs, generates less heat.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
Marketing FeaturesWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Local and web-based monitoringStatus available to customers both in the data center and remotely.AvailabilityAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.AgilityRack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
APC is the industry leader in network and server UPSsSmart-UPS with lithium-ion batteries saves up to 47% in Total Cost of Ownership (TCO) over the lifetime of the UPS. Battery life is increased 2X. Reduced maintenance cost and improved battery performance in temperatures up to 104°F. UPS management options include Powerchute Business Edition, APC SmartConnect, Network Management Cards and EcoStruxure IT. The additional benefit of a 12-inch short-depth chassis allows this UPS to be installed in any 4-post rack and most wall-mount racks. The APC Smart-UPS Lithium-ion (Li-ion) UPS provides pure sine wave output power protection for servers, voice/data networks, medical labs and light industrial applications. As one of the world’s largest and most respected power protection designers and manufacturers, APC is relied upon daily for power protection and availability. APC products offer the maximum level of protection, safety, convenience, and reliability. Everything you love about Smart-UPS now with lithium-ion batteries! APC is the industry leader in network and server UPS- Lithium-Ion battery provides twice the services life of the lead-acid batteries typically used in (Uninterruptible Power Supplies) UPS- Intelligent battery management system Li-ion batteries are monitored at an individual cell level to manage voltage and temperatures of the set of cells. This helps the Li-ion batteries to provide a higher level of safety. - High-efficiency green mode Achieves up to 97% percent efficiency, which minimizes utility and cooling costs without compromising performance or reliability. Smart-UPS SMTL1500RM3UC- Alphanumeric LCD Display Intuitive interface provides detailed and accurate information with ability to configure locally-function LCD display- Built-in energy meter Measures energy use and displays UPS efficiency in various modes of operation for easy energy tracking.- Flash upgradeable firmware Allows for field updates of firmware via communication ports or Network Management Card (NMC)Smart-UPS SMTL1500RM3UCSwitchable outlet group Ability to control a group of output load receptacles independent from the main UPS. Enables:- Cycling the entire UPS- Sequenced turn ON/OFF- Shedding of noncritical loads based on a variety of parameters (battery time, runtime remaining, and overload)- Scheduled time OFF to conserve energy- Rebooting hung device without
APC STABILIZING FEET FOR SMTL 1000/750VA
APC Smart-UPS 2200VA LCD RM 2U 120V with L5-20PReliable network power protection designed for deployment in retail and open access environments.Includes : CD with software , Documentation CD , Rack Mounting brackets , Rack Mounting support rails , Smart UPS signalling RS-232 cable , USB cable- Cold-start capableProvides temporary battery power when the utility power is out.- Energy meterProvides actual kilowatt hours of usage for energy conscious users.- Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.- High online efficiencyReduces utlility costs, generates less heat.- Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.- Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.- Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.- Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.- Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.- SmartSlotCustomize UPS capabilities with management cards.- StruxureWare Data Center Expert compatibleEnables centralized management via StruxureWare Data Center Expert.- Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
Accessory solutions to tailor the Smart-UPS to meet your specific needs.
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).InfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance.
APC SMX2000LVNC. Output power capacity: 1.92 kVA, Output power: 1800 W, Waveform: Sine. AC outlet types: NEMA 5–15R, NEMA 5–20R, NEMA L5-20R, Power plug: NEMA 5-20P, AC outlets quantity: 7 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 3 h. Form factor: Rackmount/Tower, Product color: Black, Rack capacity: 2U. Width: 17" (432 mm), Depth: 26.3" (667 mm), Height: 3.35" (85 mm)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
