APC SCHNEIDER SCHNEIDER INROW DX 300MM CONDESING UNIT
Genuine APC RBC(TM) are tested and certified for compatibility to restore UPS performance to the original specifications.Includes Installation guideTested and approved to restore the performance of your APC UPS. Maintains UPS safety certifications (UL, VDE, CSA) and lifetime equipment protection policy (as applicable).Designed by APC by Schneider Electric exclusively for APC UPS's for complete compatibility with the intelligent battery management system.APC RBCs are safe, reliable and contain a minimum number of connections saving valuable time. Because APC RBCs are hot-swappable, no network downtime is required in order to install them.
Symmetra PX 100kW Scalable to 100kW, 208V with Startup, No Battery- Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.- Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.- Advanced electrical featuresExcellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency- Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Total Cost of Ownership- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.- 5x8 Start-up service includedRequired for full coverage of factory warranty- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.Agility- Programmable frequencyEnsures compatibility with different input frequencies.- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.- SmartSlotCustomize UPS capabilities with management cards.Sustainability- ENERGY STAR for UPSEstablishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing- EU CoC for UPSEnsures that UPSs sold in the EU are highly efficientManageability- LED status indicatorsQuickly understand unit and power status with visual indicators.- Audible alarmsProvides notification of changing utility power and UPS power conditions- Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkMarketing Features- Battery modules connected in parallelDelivers higher availability through redundant batteries.- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.- User-replaceable power modulesEnables simple upgrades and replacements of the Power Modules.- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.- Network manageableProvides remote power management of the UPS over the network.- User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.Availability- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.- Redundant Intelligence ModulesProvides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.- Swappable power modulesAllows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.- Network manageableProvides remote power management of the UPS over the network.- Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
Symmetra PX 100kW Scalable to 250kW with Left Mounted Maintenance Bypass and DistributionInfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceModular designIncreases adaptability with an open architecture configurable to any IT environment.Modular designModular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.SmartSlotCustomize UPS capabilities with management cards.Hot-swappable intelligence modulesEnsures clean, uninterrupted power to protected equipment during Intelligence Module replacement.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedConfigurable for N+1 internal redundancyProvides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Battery modules connected in parallelDelivers higher availability through redundant batteries.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
BVS240XDPDR 24V DC UPS – 240Watt, 24V, 10A, DIN-Rail mounting, Power Module without batteryProtectyour investment and prevent data loss with the new 240Watt 24V DC DIN-rail mounted industrial UPS from Schneider Electric, which provides reliable surge protection and battery backup during power failures in an industrial environment.This Schneider Electric Industrial UPS enables machine builders and system integrators to:efficiently manage their automation equipment in the event of a power failure.Separate batteryThe BVS240XDPDR power module is equipped with DC input/output terminals to support PLCs and HMIs, and must be equipped with a minimum of 1 and a maximum of 4 XB005XPDR runtime batteries. This allows for up to one hour of bridging time during power failures under full load. See runtime table for more details. The Industrial DC DIN Rail UPS comes with relay contactors that enable remote management of connected equipment and monitoring of the UPS.Why consider Schneider Electric Industrial UPS?-Minimize downtime and protect investments-Helps reduce machine maintenance by enabling safe shutdown of equipment during a power failure and eliminating the need to reset automation machines.-Gain better control over your industrial infrastructure with remote monitoring and management via relay contactors, external battery backup and LED indicators.Key features-24 DC inputConnect the right AC/DC or DC/DC power supply for your application.-24 DC outputDesigned to support industrial equipment such as PLCs, HMIs, industrial PCs that require a 24V DC power supply.-Relay contactorsShutdown and manage connected equipment via potential dry contacts.-Expandable battery capacityExtend runtime up to 4 batteries (XB005XPDR).-On/Off buttonRemotely turn the UPS on or off when needed.-2-year warrantyPeace of mind with a 2-year warranty.-LED indicatorsCheck the UPS status using LEDs that change from green to red when an event occurs.
High availability, ruggedized power protection for shipboard and other transportation applications.
GVSBPSU60G-WP FeaturesGalaxy VS Maintenance Bypass Panel, single unit, 10-30kW 208V, 20-60kW 480V wallmountMaintenance bypass panel for complete isolation of the UPS during service operations.
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
APC NetShelter Rack PDU Advanced, Switched, 14.4kW, 3PH, 208V, 50A, CS8365C, 42 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical loa.- APC Smart-UPS Accessories , Input: 200V, 208V, 220V, 230V, 240V, 380V 3PH, 400V 3PH- Input Connections: Hard Wire 3-wire (2PH + G), Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)- Output: 200V, 208V, 220V, 230V, 240V- Output Connections: Hard Wire 3-wire (2PH + G), Hard Wire 3-wire (H N + G)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA