High-capacity 3.3/3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface monitor load levels to prevent overloads that cause downtime.- Two single-phase L6-20P inputs with 10 ft. cords- L6-20R outlet for connecting single device or 0U vertical PDU- Automatic transfer switching within 1–5 ms- Ethernet network interface for remote access- Digital display for real-time status monitoringThe PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug. Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).Primary and Secondary Inputs for Power Redundancy- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations- Dual 10 ft. input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to separate UPS systemsBuilt-In L6-20R OutletConnects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-20P input (sold separately)Automatic Transfer Switching (ATS)- Dynamic solid-state (TRIAC) automatic transfer switching- Switches to secondary power source if primary source fails or becomes unstable- 1–5 ms transfer time ensures uninterrupted operation of connected equipment- Built-in processor prevents switching if secondary source is unavailable or of lower quality than primary sourceMultifunction Digital Display- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factorAdvanced Network Monitoring- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP- Real-time load/current data with billing-grade accuracy (+/- 1 percent)- Automated alerts help prevent overloads, power loss and downtime- Optional ENVIROSENSE module (sold separately) monitors temperature and humidityBroad Communications Compatibility- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksMounts Horizontally in 1U of Rack Space- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
Symmetra Accessories , Output Connections: NEMA L6-30R.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: NEMA L6-20P, Cord Length: 9.84 feet ( 3 meters ) , Output: 208V , Output Connections: IEC 320 C13,IEC 320 C19Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: IEC 309 16A 2P+E , Cord Length: 9.84 feet ( 3 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19 Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.- 18kW Switched 415V input 240V output PDU with built-in web/network interface- IEC309 30A Red (3P+N+E) 415V 3 phase input with 6 ft. / 1.8m line cord- 0U, 70 inch / 178cm vertical form factor- 24 switched 240V outlets (12 C13, 12 C19) in 6 separately breakered 20A single phase load banks- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase- Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
Tripp Lite PDU3V20D354B. PDU types: Basic, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 54 AC outlet(s), AC outlet types: C13 coupler, C19 coupler. Cable length: 29.9" (0.76 m). Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz. Compliance certificates: RoHS, Certification: Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS
Tripp Lite PDU3V20D354A. PDU types: Basic, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 54 AC outlet(s), AC outlet types: C13 coupler, C19 coupler. Cable length: 29.9" (0.76 m). Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz. Compliance certificates: RoHS, Certification: Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS
Smart-UPS Accessories , Input: 120V , Output Connections: NEMA 5-15R,NEMA L5-30R.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA