Tripp Lite SU20KRTHW 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU20KRTHW 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input (3 wire) and hardwire output (3 wire) connectionsSupports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / outputOptional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurationsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteriesIntelligent battery management system with temperature-compensated charging extends battery lifeUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
The APSX6048VRNET 6000W APS X Series 48V DC 208/230V AC Inverter/Charger is a reliable power source for a wide variety of power tools, computers, audio/video components and other sensitive electronics at mobile, emergency and remote sites. With no fumes, fuel or excess noise, it’s an excellent alternative to generator power. The DC-to-AC pure sine-wave inverter delivers clean power to sensitive electronics. Its automatic line-to-battery transfer switch and integrated charging system allow the unit to work as a vehicle inverter, standalone AC power source or extended-run UPS. It delivers 6000W of continuous power, 9000W up to one minute or 12000W of peak power up to 10 seconds during equipment startup or cycling. An automatic overload detector, cooling fan and resettable AC circuit breakers protect the unit from damage. Designed for easy installation in RVs, commercial and fleet vehicles, emergency vehicles and construction equipment, the APSX6048VRNET converts stored power from a 48V battery or automotive DC source to safe, stable, computer-grade AC power for unlimited runtime in heavy-load conditions. When hardwired to an external 208V or 230V AC source, the unit keeps the user-supplied battery charged via a three-stage 23/90A selectable charging system while simultaneously delivering conditioned, pure sine-wave AC power to connected equipment. When used as a UPS, the APSX6048VRNET responds to blackouts and brownouts with an automatic, instantaneous transfer to battery-derived, pure sine-wave AC power. The optional SNMPWEBSOLOHV accessory card enables remote monitoring of the unit via SNMP, SSH, Telnet, and Internet. Reliable Power for Mobile, Emergency and Remote Sites Generates 208/230V pure sine-wave power from 48V battery bank Ideal for powering variable-speed tools, computers, LEDs, fans, audio/video components and other sensitive electronics Designed for easy installation in RVs, fleet vehicles and emergency vehicles Functions as vehicle inverter, standalone AC power source or extended-run UPS Unlimited runtime with variety of user-supplied batteries Pure Sine-Wave Power for Normal and Peak Power Demands 6000W of continuous power 9000W of reserve power up to 1 min. 12000W of peak power up to 10 sec. to accommodate surge power demands during equipment startup and cycling Automatic overload detector, cooling fan and resettable AC circuit breaker protect unit from damage High-current DC input terminals for simple hardwired installation Automatic Voltage Regulation Corrects brownouts and overvoltages without using battery power during battery charging and UPS standby modes Remote Monitoring Capability DB9 port for optional SNMPWEBSOLOHV, which turns the unit into a monitored network device Enables network monitoring via SNMP, SSH, Telnet, or the Internet Automatic Transfer Switching Transfer relay switches to inverter power during blackout in 10 or 20 ms DIP switches configure high and low voltage auto-transfer 3-Stage 23/90A Selectable Battery Charger Serves as battery charger when external 208V or 230V AC power is supplied and powering connected equipment Protects battery from overcharging and overdischarging Low-battery protection prevents excessive battery depletion DIP switches configure wet/gel charging profiles Remote Generator Starter Jack Connects to separate generator with user-supplied cable to automatically cycle generator when battery level is low Rugged Steel Housing Resists moisture, vibration, impact and high-humidity environments
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.- 18kW Switched 415V input 240V output PDU with built-in web/network interface- IEC309 30A Red (3P+N+E) 415V 3 phase input with 6 ft. / 1.8m line cord- 0U, 70 inch / 178cm vertical form factor- 24 switched 240V outlets (12 C13, 12 C19) in 6 separately breakered 20A single phase load banks- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase- Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
AvailabilityBoost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Cold-start capableProvides temporary battery power when the utility power is out.Disconnected battery notificationWarns when a battery is not available to provide backup power.ManageabilityNetwork manageableProvides remote management of the UPS over the network.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial ConnectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: IEC 309 16A 2P+E , Cord Length: 9.84 feet ( 3 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19 Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable
Tripp Lite's BP480V300 External Battery Pack offers extended battery runtime when used in conjunction with compatible Tripp Lite UPS systems. Includes internal disconnect for battery isolation.Compatible UPS Systems: SVX30K to SVX210K, S3M30KX/KXD to S3M200KX/KXD, SU40K, SU60K, SU80K, SU20KX, SU40KX, SU60KX, SU80KX, SU60KTV and SU80KTV only.Offers extended-run UPS operation when used in conjunction with compatible Tripp Lite UPS SystemsMultiple battery packs can be daisy-chained through each other to the UPS for even longer extended run operation10 year design lifespan
Note: Search results and information may differ as they are provided by a third party.
In Stock*: Product stock is updated from the last business day and can change.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
