Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceHigh online efficiency Reduces utlility costs, generates less heat.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Overload protectionSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS conditionsUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)USB connectivityProvides management of the UPS via a USB port (not available on all models).Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Network manageableProvides remote management of the UPS over the network.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.
APC BN1500M2-CA
DC power into standard 120V AC power to run a wide variety of electronics, such as laptops, smartphones, tablets, game systems, portable TVs and DVD players, MP3 players and GPS units, as well as low-power lights, camping accessories, battery rechargers for small battery-operated power tools and mobile office equipment. The PV400USB features two AC outlets, a 2.1A USB port and a 1.0A USB port. Just plug the DC input jack with convenient 3-foot cord into the 12V cigarette lighter socket in your vehicle, or use the battery cables to connect to your battery - always connect red to red and black to black. Press the on/off button, and the unit is ready to operate. Easy-to-read LED lets you know the inverter is receiving power from the battery.To prevent you from running down your car battery, the PV400USB turns off automatically when the input voltage falls to 10V. Likewise, the unit will also shut down if it gets too hot (for instance, because your connected devices exceed 400 watts). A built-in ventilation fan keeps the interior cool during extended use. The durable plastic housing is engineered to withstand the rigors of road trips, campouts, business trips and family vacations. No maintenance is required.Powers and Charges Up to 4 Devices- Converts 12V DC battery power to standard 120V AC power- Runs smartphones, laptops, tablets, GPS units, game systems, portable TVs, DVD players, MP3 players and other electronics- Features 2 AC outlets, 2.1A USB port and 1.0A USB port- Outputs 400 watts (continuous); 800 watts (peak)Easy to Use- DC jack plugs into the cigarette lighter socket in your car, truck, boat or RV- Battery Cables connect directly to the battery - Always connect red to red and black to black.- Flexible 3-foot cords allows devices to run in the back seat- LED indicates the unit is receiving power from the batteryPremium Construction- Durable plastic housing built to withstand rigors of travel- Built-in ventilation fan keeps the interior cool during extended use- Automatic low-voltage shutoff prevents deep vehicle battery discharge at 10V- No maintenance required
The genuine APC Replacement Battery Cartridge (RBC) is tested and certified for 100% compatibility to the the specific APC UPS. This lead-acid RBC has a lifetime of three to five years which offers reliable support and extends the useful life of your UPS. The APC RBC comes fully assembled and ready for use. To see the compatible UPS list, please click View Compatible UPS Modelsbutton in Get Support Section at APC.com
16/20A single phase 208/230V Local Metered Power Distribution Unit / rack PDU (rPDU) (Agency de-rated to 16A continuous)Built-in 2 digit visual meter continuously reports PDU load level in ampsC20 inlet with C20 input cable and L6-20P adapter; 12-ft. (3.66 m) line cord1U horizontal rackmount format installs in one rack space10 total outlets (8 C13 / 2 C19)Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationOptional PDUSIDEBRKT enables 0U vertical rackmount in compatible racksBack panel grounding lugFederal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Integrates with InfraStruXure CentralAn IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
