Backup Battery Module Gives Your Compatible UPS System Extended RuntimeThe valve-regulated lead-acid (VRLA) BP48RT offers extended battery runtime when used in conjunction with SU1500RTXLCD2U, SU1500RTXLCDN, SUINT1000LCD2U and SUINT1500LCD2U SmartOnline® UPS systems. It can also be daisy-chained for a maximum of four matching battery packs to deliver even longer extended-run operation. Heavy-gauge cabling with high-current DC connectors is included for safe, simple installation. Versatile Installation OptionsYou can mount the BP48RT in 2U of space in an EIA-standard 19-inch rack using the included 4-post rail kit or an optional 2-post rail kit (RK2PC, sold separately). You can also adapt it for tower installation using the UPS system’s support stands.
The PDUH20DV 1.6-3.8kW Single-Phase 100-240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUH20DV features 14 total outlets—four C13 in front and eight C13 and two C19 in the rear.The C20 input plug with detachable 12-ft. (3.66 m) cord connects to your facility's compatible AC power source, generator or protected UPS to distribute power to connected equipment. A NEMA L6-20P adapter is included for 208/240V power environments. The C20 inlet accepts any country-specific power cord with a C19 connector.The switchless design prevents an accidental shutdown, which could lead to costly downtime. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA-standard 19-inch racks, under a counter or on a wall or workbench.
9PX battery pack, Used with 9PXK3UN, 9PX5K, 9PX6K, 9PX6KUS, 9PXEBM180RT, 9PXEBM360SP, Hot-Swappable internal batteries EBMs, Single-phase, lead-acid battery.
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.- Tripp Lite SMART2200RM2U line interactive 2U rack/tower UPS with 2200VA / 2.2kVA / 1920W capacity- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V- NEMA 5-20P input plug; 4 NEMA 5-15R & 4 NEMA 5-15/20R output receptacles, Two independently switchable output load banks- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages- High 96% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions- Internal batteries offer 12 minutes at 50% load (960W) and 4.5 minutes at 100% load (1920W)- Hot-swappable, user-replaceable internal batteries can be replaced with no disruption to connected equipment- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information- LCD interface also supports a number of advanced user setup and operating preferences- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement- Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options- HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
SRT3000RMXLA-NCFeaturesAPC Smart-UPS SRT 3000VA RM 120V Network CardHigh density, double-conversion on-line power protection with scalable runtimeIncludes : CD with software , Documentation CD , Installation guide , Network Management Card , Rack Mounting brackets , Rack Mounting support rails , USB cable , Warranty card- 10/100 BaseT ConnectionConnect the device to a network using a 10 or 100 BaseT connection- Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance- ECO ModeOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection- Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.- LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.- Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Serviceability- Audible alarmsProvides notification of changing utility power and UPS power conditions- Disconnected battery notificationWarns when a battery is not available to provide backup power.- Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.- Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.- User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Protection- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.- Cold-start capableProvides temporary battery power when the utility power is out.- Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.- Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.- Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.- Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Manageability- Network manageableProvides remote power management of the UPS over the network.- Serial connectivityProvides management of the UPS via a serial port.- SmartSlotCustomize UPS capabilities with management cards.- LED status indicatorsQuickly understand unit and power status with visual indicators.- InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.Adaptability- Plug-and-Play external batteriesEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.- Flash upgradeable firmwareInstall maintenance releases of firmware remotely using FTP.- Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Availability- Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.- Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.- Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.- Scalable runtimeAllows additional run time to be quickly added as needed.- Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.- Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedMarketing Features- Avoids costly power problems by keeping your IT equipment and data protected and available.Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.- Low operating and maintenance costs with proven reliability and intelligent battery management.Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.- Save time with easy and convenient remote accessibility.Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.- Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
The Smart 2-Port USB Car Charger is an ideal solution for charging mobile devices while on long road trips or short commutes. This high-performance car charger features a compact design for easy portability and provides a power output of 5V and 2.4A for device charging.The charger includes two USB-A ports to charge two devices at once. The Smart-IC technology identifies the mobile device's unique charging requirements to safely charge at the maximum speed. Having the ability to detect the accurate current output allows for protection against overloads, which can damage valuable mobile devices.5 volts and 2.4 amps of power are available for device charging from this adapter when it is plugged into a DC outlet. The 2.4 amps are shared by the two ports. The power output makes this adapter the perfect solution for charging smartphones and tablets.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA