Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.- 15A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 12A continuous)- Attached NEMA 5-15P 120V single phase input; 12 ft. / 3.6m cord- 1U horizontal rackmount form factor- 16 switched NEMA 5-15R outlet (8 front / 8 rear)- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and total output load level in amps- Digital display continuously reports total output load level in amps- Supports user-specified alarm notification thresholds- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- 1U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets- Adjustable mounting brackets enable installation in 2 or 4 post racks, plus additional support for wallmount and under-counter mounting- Included cord retention brackets- TAA Compliant Version Available - Order Tripp Lite PDUMH15NETAA
Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 20A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 16A continuous)- Two-digit lighted meter reports combined total output current in amps- Attached NEMA L5-20P input plug with 15ft / 4.6m line cord and 5-20P adapter- 0U 60in / 152cm vertical rackmount format installs using no rack spaces- 28 NEMA 5-15/20R outlets- Includes 20A circuit breaker and lighted power switch inside a transparent protective cover- Toolless installation supported in button-mount compatible equipment racks- Bolt-down installation brackets support installation in other racks and additional surfaces
Tripp Lite Metered ATS / Auto Transfer Switch PDU systems enable redundant power configurations for network devices with a single input cord connection. Set of two ATS inputs support connection to separate PRIMARY and SECONDARY power sources. The ATS normally maintains continuous output to connected equipment derived from the primary input. If the primary input fails or becomes unstable, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources to support a variety of advanced redundant power networking applications. Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time, similar to Tripp Lite SmartOnline series. ATS configurations utilizing separate mains circuits, backup generators and even out-of-phase power sources are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front panel current meter offers selectable 4 segment voltage, amperage and kilowatt loading information.- 208V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)- Provides a redundant power option for critical networking equipment with a single input power cord- Digital display with selection button reports voltage, amperage and kilowatt loading information in four output segments (Segment 1: 8 C13 & 1 C19 outlets / Segment 2: 8 C13 & 1 C19 outlets / Segment 3: L6-30R outlet / Segment 4: total output of all outlets combined)- 19 built-in outlets (16 C13, 2 C19, 1 L6-30R)- Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY power sources- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output as sourced from the secondary input cable until power on the primary input is restored and stable- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a 2 UPS environment, the primary input must be connected to an online double conversion UPS similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Super-fast switchover between primary and secondary power sources occurs in 1-5 milliseconds- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH30HVATAA
208/230V Switched Power Distribution Unit / rack PDU (rPDU) with built-in web/network interface (12A 208V and 10A at 230V)C14 power inlet accepts a wide variety of worldwide input cord optionsIncludes 6.5 ft. / 2m C14 cable1U horizontal rackmount form factor8 switched C13 outletsSupports power-on, power-off or reboot of each outlet on a real-time or programmable basisEnables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outletsPre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsIP-based Auto Probe detects lost connectivity and restores service autonomouslyIn-rack environmental reporting with optional temperature, humidity and contact-closure sensor options10/100 Mbps auto-sensingIncluded cord retention brackets keep vital network equipment plugged in and continuously powered
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA