Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution for critical IT equipment in wiring closets, server rooms and equipment racks. Supplies continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 5.8kW 30A 208/240V single phase Basic Power Distribution Unit / PDU- 1U horizontal 19 inch rackmount form factor installs in one rack space- NEMA L6-30P 30A 208/240v input plug with 15 ft. / 4.5m line cord- 20 outlets (4 C19, 4 C13 front / 12 C13 rear)- Adjustable mounting brackets enable installation in 2 or 4 post racks, plus additional support for wallmount and under-counter mounting- Mounting ears are reversible for front or rear facing rackmount installation- Back-panel grounding lug
Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution. Supplies equipment with continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- PDUV20 offers highly reliable 20A 120V power distribution in a 36 in. / .9m 0U vertical rackmount format (Agency de-rated to 16A continuous)- 14 NEMA 5-15/20R output receptacles- NEMA L5-20P input plug and 5-20P adapter- 15 ft. / 4.6m attached line cord- 20A resettable circuit breaker- Switch-free design prevents accidental shutoff- Toolless mounting buttons enable simple installation in Tripp Lite and other button-mount compatible equipment racks- Rear facing installation buttons can be relocated to the left or right surface of the PDU for rear, center or forward-facing outlet orientation in compatible racks- Included nut and bolt mounting brackets support installation in non button-mount compatible racks, wallmount and raceway applications
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduledmaintenance. But what if you are unable to afford the costly downtime involved in powering down forregular upkeep? This 120V 20A single-phase hot-swap PDU works in conjunction with your UPS systemto keep everything running 24/7/365. It allows you to manually transfer connected equipment to utilitypower via the PDU’s bypass switch, permitting maintenance or equipment replacement with nointerruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUB201U includes separate UPS and utility input cables with NEMA 5-20P plugs. The manualtransfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace theUPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipmentconnected to the six NEMA 5-20R outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled 5-20Routlets all at once when the device connected to the master 5-20R outlet is powered off or goes into a lowpower consumption mode.Mounts into 1U of Rack Space or WallUse the included mounting hardware to install the PDUB201U’s all-metal housing into 1U of space in anEIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.- 15A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 12A continuous)- Attached NEMA 5-15P 120V single phase input; 12 ft. / 3.6m cord- 1U horizontal rackmount form factor- 16 switched NEMA 5-15R outlet (8 front / 8 rear)- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and total output load level in amps- Digital display continuously reports total output load level in amps- Supports user-specified alarm notification thresholds- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- 1U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets- Adjustable mounting brackets enable installation in 2 or 4 post racks, plus additional support for wallmount and under-counter mounting- Included cord retention brackets- TAA Compliant Version Available - Order Tripp Lite PDUMH15NETAA
Tripp Lite PDUV30-36. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 12 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-30P. Cable length: 120.1" (3.05 m). Nominal input voltage: 100 - 127 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.19" (55.6 mm), Depth: 3.75" (95.2 mm), Height: 36" (914.4 mm)