Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Cold-start capableProvides temporary battery power when the utility power is out.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.High online efficiencyReduces utlility costs, generates less heat.Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.SmartSlotCustomize UPS capabilities with management cards.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Network manageableProvides remote power management of the UPS over the network.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedBattery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenancePredictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Resettable circuit breakersEnables a quick recovery from overload events.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systemsLow operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.Save time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
APC Smart-UPS 3000VA LCD RM 2U 120V with Network CardAdjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Audible alarmsProvides notification of changing utility power and UPS power conditionsAutomatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceBoost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.Disconnected battery notificationWarns when a battery is not available to provide backup power.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedIntelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Network manageableProvides remote power management of the UPS over the network.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.Serial connectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.USB connectivityProvides management of the UPS via a USB port (not available on all models).ManageabilityLED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.Network manageableProvides remote power management of the UPS over the network.Marketing FeaturesPeace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systemsSave time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.AvailabilityBoost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Disconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.AdaptabilityAdjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.ServiceabilityResettable circuit breakersEnables a quick recovery from overload events.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedPredictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.SafetySafety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Tripp Lite's SMART1000LCD Line-Interactive Digital UPS System offers voltage regulation, surge suppression and long-lasting battery support for personal computers, network workstations, home entertainment systems and media centers. Internal UPS circuits support entry-level PCs for up to 60 minutes or individual DVR components for as long as 3 hours during power failures. Prevents data loss, viewing interruptions, lost recordings and loss of component programming. Automatic Voltage Regulation (AVR) circuits regulate brownouts as low as 89 volts back to usable levels without using battery power. Offers complete power protection in an attractive black tower configuration. Includes 4 battery-supported outlets, plus 4 additional surge suppression-only outlets for items not requiring battery support. Space saving right angle 5-15P input plug.USB port enables optional unattended system shutdown without data loss in the case of extended power failure, USB cable included. HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows and Mac OS X. Full load efficiency rating of 97% offers energy-savings and cool operating temperatures. Built-in single-line RJ-11 phone suppression jacks protect modem, satellite receiver or other peripherals with a standard dialup/DSL phone connection. Set of 2.2 GHz coaxial jacks protect against surges entering on CATV, satellite or broadcast antenna connections. Built-in audible alarm and large LCD front panel voltage display indicates line power status, battery power status, battery low/replace status and voltage boost operation.The LCD display includes a dimmer switch and can be rotated for easy viewing in upright tower or horizontal shelf-mount position. 1000VA/500W power-handling ability supports entry-level PCs, home entertainment systems, network workstations, audio/video components.- LCD Display with dimmer switch indicates input voltage, battery capacity and a variety of operating conditions. Display is rotatable for easy viewing whether UPS is in vertical or horizontal position- SMART1000LCD Digital Uninterruptible Power Supply offers voltage regulation, surge suppression and long lasting battery support during blackouts- Full load efficiency rating of 97% offers energy-savings and cool operating temperatures- Supports entry level PCs up to 60 minutes or single DVR components for up to 3 hours during blackouts- Regulates brownouts as low as 89 volts back to usable levels without using battery power- 4 UPS battery supported outlets, plus 4 additional surge suppression-only outlets- Space saving right angle 5-15P input plug- USB port and cable enables unattended shutdown in the case of extended power failure- HID-compliant USB port enables full integration with built-in power management and auto shutdown features of Windows and Mac OS X- Single-line phone suppression protects standard dialup/DSL phone connection- 1000VA/500 watt power handling ability supports a variety of sensitive computer, home theater and other equipment- 3 minutes full load runtime (1000VA/500 watts), 10 minutes half load runtime (500VA/250 watts)- Cabinet adapts to tower format or rackmount shelf format. Rackmount (2U) format requires an optional shelf, available separately- Supports battery replacement via built-in access panel- Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment- $250,000 connected equipment insurance (USA, Canada & Puerto Rico Only)
Tripp Lite AVR900U. UPS topology: Line-Interactive, Output power capacity: 0.9 kVA, Output power: 480 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 12 AC outlet(s). Battery voltage: 12 V, Typical backup time at full load: 2.7 min, Typical backup time at half load: 10 min. Form factor: Tower, Product color: Black, Housing material: Acrylonitrile butadiene styrene (ABS). Width: 7.48" (190 mm), Depth: 12" (304.8 mm), Height: 4.14" (105.2 mm)
FeaturesIntelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.Cold-start capableProvides temporary battery power when the utility power is out.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.High online efficiencyReduces utility costs, generates less heat.Lithium-ion batteryLithium-ion batteries provide twice the service life of a typical lead acid battery and are small, light and environmentally friendly.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Short-depth rack compatibilityCompact design fits comfortably in short-depth rack applications.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.SmartConnectInnovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.SmartSlotCustomize UPS capabilities with management cards.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.SafetySafety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.AdaptabilityAdjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.ServiceabilityUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced.Predictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Resettable circuit breakersEnables a quick recovery from overload events.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance.ManageabilityAudible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.Network manageableProvides remote power management of the UPS over the network.Serial connectivityProvides management of the UPS via a serial port.Disconnected battery notificationWarns when a battery is not available to provide backup power.LED status indicatorsQuickly understand unit and power status with visual indicators.USB connectivityProvides management of the UPS via a USB port (not available on all models).Save time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems.Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
APC BK350. Output power capacity: 0.35 kVA, Output power: 210 W, Input frequency: 50/60 Hz. Typical backup time at full load: 4.7 min, Typical backup time at half load: 18.1 min, Battery recharge time: 8 h. Product color: Beige, Cable length: 70.9" (1.8 m), Safety: UL/FCC/CE/C-Tick. Weight: 13.2 lbs (5.98 kg). Package weight: 14 lbs (6.36 kg)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA