Mobile Surface Hub 2S & Surface Hub3The APC Charge Mobile Battery enables unlimited wireless collaboration on the Microsoft Surface Hub 2S & 3 (>100 min.) Thanks to the APC battery, mounted in the Steelcase Roam stand, you can use the Surface Hub wherever and whenever you want, without being limited to a single room with a power socket. Imagine that every inspiring environment is suddenly suitable for creative teamwork. This way you always stay online, your data is always saved and deleted and you never lose the creative momentum again.Integrated designIn collaboration with Steelcase, we have developed the Roam, a mobile stand in which you can seamlessly and hiddenly integrate the APC Battery: CSH2. The result? A clean and functional design that is not limited to a single room.Easy installationYou place, attach and connect the APC battery in an instant.WarrantyThe factory warranty of the CSH2 is 3 years, with the APC service pack (WBEXTWAR3YR-SP-04) this is extended by 3 years to 6 years.What's in the box:-CSH2- DC cable- IEC C13 to IEC C14 power cord- Screws- USB cable- User manualAPC Smart-UPS Charge Mobile Battery is a lithium-ion battery system designed to power Microsoft Surface Hub 2S and Surface Hub 3 on-the-go, so you stay connected regardless of the location.
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceHigh online efficiencyReduces utlility costs, generates less heat.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Overload protectionSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltageregulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS power conditionsUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)USB connectivityProvides management of the UPS via a USB port (not available on all models).Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Network manageableProvides remote power management of the UPS over the network.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.
APC STABILIZING FEET FOR SMTL 1500VA
APC BGM1500B-CA
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).InfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.High online efficiencyReduces utlility costs, generates less heat.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
Vertiv Liebert GXT5LI-1500LVRT2UXL. UPS topology: Double-conversion (Online), Output power capacity: 1.5 kVA, Output power: 1350 W. AC outlet types: NEMA 5-15R, Power plug: NEMA 5-15P, AC outlets quantity: 6 AC outlet(s). Battery technology: Lithium-Ion (Li-Ion), Typical backup time at full load: 14 min, Typical backup time at half load: 28 min. Form factor: Rackmount, Product color: Black, Rack capacity: 2U. Compliance certificates: REACH, RoHS, WEEE
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA