Smart-UPS Accessories , Input: 100V, 120V , Output Connections: NEMA 5-15R,NEMA 5-20R,NEMA L5-20R.
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loadsPDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option2U horizontal rackmount form factor compatible with 2 or 4 post racksSupports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported)8 C13 outlets support critical networking loads in both Utility and UPS operating modesOne additional C13 pass-through outlet supports UPS input power cordDual input power cables support PDU connection to separate Utility and UPS power sourcesManual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPSSet the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPSSet the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh oneOnce the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
11.5kW Switched 360-415V input 208-240V output PDU with built-in web/network interfaceIEC309 16/20A Red (3P+N+E) 360-415V 3 phase input with 6 ft. / 1.8m line cord0U, 70 inch / 178cm vertical form factor30 switched 208-240V outlets (24 C13, 6 C19) in 3 single phase load banksSupports power-on, power-off or reboot of each outlet on a real-time or programmable basisEnables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outletsNetwork interface provides PDU control and data regarding input voltage and load levels per-outlet and per-phaseBuilt-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientationSupports user-specified alarm notification thresholdsDHCP/Manual configuration support10/100 Mbps auto-sensingReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browserAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancementsSupports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocolsFully compatible with FREE PowerAlert Network Management System / NMS SoftwareIncluded set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outletsToolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Accessories to upgrade and expand your installed APC power distribution units.
APC Switched Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E , Cord Length: 6 feet ( 1.83 meters ) , Output: 208V, 230V , Output Connections: IEC 320 C13,IEC 320 C19.Includes: Installation guide, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: IEC 309 16A 2P+E , Cord Length: 9.84 feet ( 3 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19 Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: NEMA L6-20P, Cord Length: 9.84 feet ( 3 meters ) , Output: 208V , Output Connections: IEC 320 C13,IEC 320 C19Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable.