High-capacity 3.3/3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface monitor load levels to prevent overloads that cause downtime.- Two single-phase L6-20P inputs with 10 ft. cords- L6-20R outlet for connecting single device or 0U vertical PDU- Automatic transfer switching within 1–5 ms- Ethernet network interface for remote access- Digital display for real-time status monitoringThe PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug. Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).Primary and Secondary Inputs for Power Redundancy- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations- Dual 10 ft. input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to separate UPS systemsBuilt-In L6-20R OutletConnects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-20P input (sold separately)Automatic Transfer Switching (ATS)- Dynamic solid-state (TRIAC) automatic transfer switching- Switches to secondary power source if primary source fails or becomes unstable- 1–5 ms transfer time ensures uninterrupted operation of connected equipment- Built-in processor prevents switching if secondary source is unavailable or of lower quality than primary sourceMultifunction Digital Display- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factorAdvanced Network Monitoring- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP- Real-time load/current data with billing-grade accuracy (+/- 1 percent)- Automated alerts help prevent overloads, power loss and downtime- Optional ENVIROSENSE module (sold separately) monitors temperature and humidityBroad Communications Compatibility- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksMounts Horizontally in 1U of Rack Space- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Symmetra Accessories , Output Connections: NEMA L6-30R.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: NEMA L6-20P, Cord Length: 9.84 feet ( 3 meters ) , Output: 208V , Output Connections: IEC 320 C13,IEC 320 C19Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable.
APC Switched Rack PDU , Input: 200V, 208V, 230V , Input Connections: IEC 309 16A 2P+E , Cord Length: 9.84 feet ( 3 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19 Includes: Installation guide, Locking input power cord, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.- 18kW Switched 415V input 240V output PDU with built-in web/network interface- IEC309 30A Red (3P+N+E) 415V 3 phase input with 6 ft. / 1.8m line cord- 0U, 70 inch / 178cm vertical form factor- 24 switched 240V outlets (12 C13, 12 C19) in 6 separately breakered 20A single phase load banks- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase- Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
Rack PDU 2G, Switched, ZeroU, 30A, 100-120/200-240V 2Ph, (16) 5-20R (7) C13 (1) C19APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
11.5kW Switched 360-415V input 208-240V output PDU with built-in web/network interfaceIEC309 16/20A Red (3P+N+E) 360-415V 3 phase input with 6 ft. / 1.8m line cord0U, 70 inch / 178cm vertical form factor30 switched 208-240V outlets (24 C13, 6 C19) in 3 single phase load banksSupports power-on, power-off or reboot of each outlet on a real-time or programmable basisEnables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outletsNetwork interface provides PDU control and data regarding input voltage and load levels per-phaseBuilt-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientationSupports user-specified alarm notification thresholdsDHCP/Manual configuration support10/100 Mbps auto-sensingReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browserAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancementsSupports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocolsFully compatible with FREE PowerAlert Network Management System / NMS SoftwareIncluded set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outletsToolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Note: Search results and information may differ as they are provided by a third party.
In Stock*: Product stock is updated from the last business day and can change.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
