APC ACCD75214 evaporative air cooler Roof-mounted evaporative air cooler
The SRCOOL24K SmartRack 24,000 BTU 208/240V Portable Air Conditioning Unit cools, dehumidifies and filters the air in your server room, data center or other environment with heat-sensitive equipment. The compact, portable unit fits into just 4 square feet of floor space. It is designed for primary, supplemental or backup cooling of IT equipment to prevent shutdowns, malfunctions and costly downtime caused by overheating or fluctuating temperatures.The self-contained SRCOOL24K packs 24,000 BTU/h(7kW) of cooling capacity into a rack-width chassis. A built-in evaporator expels condensation through a directional exhaust duct, eliminating the need for a floor drain or water collection tank. The SRCOOL24K also dehumidifies and filters the air, providing better air quality that can enhance equipment performance. Efficient close-coupled cooling reduces energy use and operating costs.Installation is quick and easy and does not require disruptive construction or the costly expense of hiring a plumber or HVAC specialist. The unit rolls into place on durable built-in casters. The NEMA L6-20P plug connects to a standard 208/240V 20A outlet. The SRCOOL24K restarts automatically after power failures, and a built-in timer supports unattended shutdown and startup.The included SRCOOLNET2 network management card lets you monitor temperatures, receive alerts, review logs, automate operation and control settings from anywhere via SNMP, web browser, SSH or telnet. The SRCOOLNET2 includes the ENVIROSENSE remote sensor, which lets you monitor temperature and humidity up to 12 feet away from the SRCOOL24K.Portable, High-Capacity Cooling Power- Produces 24,000 BTU/h(7 kW) of cooling capacity in a portable, rack-width chassis- Prevents equipment shutdowns, malfunctions and failures caused by overheating and temperature fluctuations- Filters and dehumidifies the air to enhance equipment performance- Uses environmentally friendly R410A refrigerant, which complies with worldwide standards- Efficient close-coupled cooling reduces energy use and operating costsConvenient Operation- Adjustable louvers support area cooling applications- Flexible dual output ducts aim cold air where it’s needed, such as an overheated rack enclosure or equipment hot spot- Supports unattended shutdown and startup, including automatic restarts after power failures- Easy-to-read control panel with digital display and diagnostic LEDs for local management- System-lock function disables all other buttons to prevent accidental inputAdvanced Network Monitoring- Included SRCOOLNET2 accessory allows remote monitoring of temperatures, alerts, logs and control settings from anywhere via SNMP, web browser, SSH or telnet- ENVIROSENSE remote sensor monitors temperature and humidity up to 12 ft. awayEasy to Install- Rolls into place on built-in casters- Fits into 2 x 2 ft. section of floor space- 6.5 ft. power cord with NEMA L6-20P plug connects to a standard 208/240V 20A AC outlet- No external condenser, refrigerant piping or professional maintenance required- Built-in evaporator expels condensation through exhaust tube—no floor drain or water collection tank needed- Exhaust kit removes hot air from room through drop ceiling, window or return duct- Includes all parts required for setup
12,000 BTU of Cooling Power Protects Your Equipment Against Hazardous High HeatThis SmartRack® server rack cooling unit is a portable, compact, self-contained air conditioning unit designed for small server rooms, IT and network closets, back offices and other areas with heat-sensitive equipment that facility air conditioning can’t reach. It pumps 12,000 BTU (3.5kW) of cooling into your IT environment to help prevent shutdowns, malfunctions and other failures caused by overheating or fluctuating temperatures. It uses environmentally friendly R290 refrigerant to comply with worldwide standards. An easy-to-read control panel with diagnostic LEDs provides convenient local management.Rack/Spot Cooling Focuses Cold Air Where It’s Most NeededClose-coupled cooling delivers cold air near heat loads to discourage recirculation and increase energy efficiency. An included 71-inch flexible hose lets you aim the cold air to a specific spot, such as an overheated rack enclosure or an equipment hot spot. Hot air exits through a window or drop ceiling via an included exhaust kit. A hot air exhaust fan maintains effectiveness even under a high heat load. The unit also dehumidifies and filters the air, providing better air quality that can enhance operating conditions and equipment reliability. Special Commercial-Grade Components for Reliable PerformanceWith a 100-percent duty cycle, the SRXCOOL12KEU can run continuously without costly downtime. It uses copper tubing that is stronger than the aluminum tubing used in most consumer cooling units. The copper allows higher pressures and better weld joints to stand up to the constant vibration of the running compressor.Built-In Evaporator Ensures No Water Collection Tank to EmptyThe evaporator expels the condensed water through the directional exhaust duct, eliminating the need for a drain tube, drain pan or water collection tank and saving you time and money. No external condenser, refrigerant piping or professional maintenance is required for simple operation. Upgraded firmware allows the compressor to cycle on and off while the evaporator fan stays on to prevent icing in high-humidity environments.Add an Optional Remote Management Accessory for 24/7 Monitoring and ControlInstall the optional SRCOOLNETLX network module (sold separately) to monitor temperatures, receive alerts, review logs and control settings from anywhere, anytime, via SNMP, web browser, SSH, telnet or command line interface. The built-in LX Platform’s PowerAlert® Device Manager provides a single interface to cycle the connected air conditioner on and off, adjust its fan speed, change its target set point temperature and switch to dehumidification mode.Designed for Simple Plug-and-Play Installation by Almost AnyoneThe self-contained SRXCOOL12KEU requires no disruptive construction projects or costly service calls from plumbers or HVAC specialists. It rolls on four casters into a compact 12 x 20 inch area. The 6 ft. (1.83 m) power cord with leakage current protection connects to a Schuko CEE7 outlet. The unit is programmed to restart automatically after power failures, and a built-in timer allows unattended shutdown and startup. An upgraded motor-start capacitor with a larger capacity ensures a dependable startup.
Tripp Lite SRCOOL2KWM. AC input voltage: 120 V, AC input frequency: 60 Hz. Product color: Black, Housing material: Steel, Display type: LCD. Width: 13.5" (342.9 mm), Depth: 13.5" (342.9 mm), Height: 11.1" (281.9 mm). Master (outer) case width: 19.6" (497.8 mm), Master (outer) case length: 23.6" (599.4 mm), Master (outer) case height: 16.9" (429.3 mm)
Split Unit Outdoor Condensing Unit 6KW 208-230/1/60Split system units and integrated free-cooling systems for outdoor installationsAutomatic restartReturns the unit to its last operating status in the event of a power failure.Building Management SystemsUnits are designed to work with the most common BMS systems including BACnet and Modbus.Cost EfficientBudget conscious solution to enhance airflow within enclosureEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Zero White SpaceAll cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.Scroll compressorsUtilize few moving parts for increased reliability and life expectancy.Dual power inputs(Optional) Dual power supplies for incoming power redundancyDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
Split Unit Ceiling Mount Evaporator 6KW 208-230/1/60Split system units and integrated free-cooling systems for outdoor installationsAir filtrationRemoves dirt and other particulates from the intake air for cleaner supply air.Automatic restartReturns the unit to its last operating status in the event of a power failure.Building Management SystemsUnits are designed to work with the most common BMS systems including BACnet and Modbus.Cost EfficientBudget conscious solution to enhance airflow within enclosureDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Dry contact outputProvides remote notification of failures when used with APC environmental monitoring unit or system.Dual fansProvides fault tolerance in the event of a fan failure.Ease of UseSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.EconomizationAchieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.Electronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.LED status indicatorsQuickly understand unit and power status with visual indicators.Microprocessor controllerThe system is controlled by a microprocessor, with an 80-character LCD backlit alphanumeric display, that provides communication and alarm indication.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Remote monitoring supportWeb-based service that serves as a second set of eyes into the health of a company's physical infrastructure. Experienced professionals work non-stop to provide 24-hour monitoring and to help diagnose problems before they become critical.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Temperature DisplayMonitors and displays temperature to prevent overheating.Scroll compressorsUtilize few moving parts for increased reliability and life expectancy.Dual power inputs(Optional) Dual power supplies for incoming power redundancyDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA