PROMISE TECHNOLOGY VESS RAID 2K 4G DDR3 MEM MOD UPGRADE/RE
FOR DRIVESTATION DUO MODELS
Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.ServiceabilityEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.AgilityScaleable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Modular designModular design provides scalable solutions to add cooling as demand increases.Total Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.In-Row architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.AvailabilityRack inlet temperature controlReduces the risk of hot spots at the rack levelActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.ManageabilityBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.Real-Time capacity monitoringReal-time display of current and available cooling.Microprocessor controllerUtilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
APC ACCS1007 rack accessory Mounting bracket
APC ACDC2552 rack accessory Depth adapter
Availability Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Rack Inlet Temperature Control Reduces the risk of hot spots at the rack level Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Total Cost of Ownership Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods. In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures. Agility Modular design Modular design provides scalable solutions to add cooling as demand increases. Scaleable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Active Airflow ControlMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Air filtrationRemoves dirt and other particulates from the intake air for cleaner supply air.Architecturally neutralUnobtrusive design and coloring, blends in with the surroundings.Capacity ControlCooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.CastersProvides flexibility to move the unit to wherever cooling is required.Containment system compatibleThe unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiencyContinuous current monitoringPermits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.Ease of UseSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.Easy to installInnovative design allows for fast, easy installation by almost anybody.EfficiencyIncreases the capacity of the air conditioner by supplying a warmer return air temperature.Electronic expansion valveRefrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoringElectronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.Enclosure system compatibleSpecifically designed to work with Netshelter Enclosures.Fan guardsA safety measure that provides protection from the fan opening by covering the inlet.Fault-tolerant fan systemIn the event of a fan failure, the remaining fan(s) will continue to operate.Field replaceable componentsFans and electronics module can be readily replaced without uninstalling the unit.FlexibilitySupport for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containmentFront service accessThe system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.Green RefrigerantEnvironmentally friendly refrigerant that can offer LEED points.Hardwire capableFor installations where hard wiring is required or prefered.Head pressure controlModulates refrigerant head pressure to protect from coil freeze.High Sensible-to-Total Cooling RatioAchieved by careful sizing of heat exchanger coils.Horizontal airflow patternRemoves heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.Increased capacityHigher rate of heat removal allows more equipment to be installed in each rack.Local area networkCreates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situationsMinimizes Air MixingDelivers cool, conditioned air directly to the inlet of IT equipment.Modular strategyModular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Operational efficiencyWarmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Predictive failure notificationMaximizes system availability by providing early warning of required fan or filter replacement.Programmable input/output contactsAllows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.Rack Inlet Temperature ControlReduces the risk of hot spots at the rack levelReal-Time Capacity MonitoringReal-time display of current and available cooling.Rear containmentEnsures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Scalable DesignModular design provides scalable solutions to add cooling as demand increases.Small FootprintEfficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.Temperature DisplayMonitors and displays temperature to prevent overheating.Touch-screen GUIEnables easy configuration, full monitoring, and event logging
IT enclosures designed for specific environments and applications.Includes: Baying hardware, Casters.
NetShelter SX cabinet and packaging system designed to safely integrate, transport, unload and deploy up to 1250 lbs (566 kg) of IT equipment The cabinet is paired with a shock absorbing pallet, unloading ramp, and impact resistant shell The system has been engineered, tested and approved for secure shipment of fully converged systems such as being certified with Cisco® for pre-racking and shipping Cisco Unified Computing System (UCS)
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Sides Without Doors Black
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA