The SUTX40K SmartOnline® SUTX Series 3-Phase 220/380V, 230/400V or 240/415V 40kVA 40kW On-Line Double-Conversion UPS provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It’s recommended for critical data center, LAN/WAN and distributed server room applications.The SUTX40K’s Voltage and Frequency Independent (VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered, even during overloads and UPS maintenance.IGBT inverter technology produces output power with 1% total harmonic distortion (THD) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.Managing the SUTX40K is simplified through the multi-language LCD interface, which displays critical operating conditions and diagnostic data, such as battery and load status. Four LEDs indicate bypass, line, battery and fault modes. A built-in card slot supports the optional WEBCARDLXE network management card for network interface and remote monitoring and control.
3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15, NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITHD 2-post rackmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).- SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications- True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time- Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values- Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)- Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches- Ships with all mounting accessories for 4 post rackmount installation- Optional 2POSTRMKITHD enables 2 post rackmount installation (not wallmount compatible)- Optional 2-9USTAND accessory enables small-footprint upright tower placement- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints- Built-in Emergency Power Off (EPO) interface with cable- NEMA L5-30P input plug; NEMA 5-15/20R & L5-30R output receptacles- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has four outlets)- Front panel LEDs offer current monitoring and battery charge level information- UPS ships fully assembled in full compliance with DOT regulations; no time consuming connection of internal batteries by user required- Single line TEL/DSL or network ethernet line surge suppression- $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Tripp Lite 8kVA SmartOnline Hot-Swappable Modular Rack/Tower UPS offers 8000VA on-line, double-conversion UPS support for server, network and telecommunications equipment. Maintains battery-derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions. Single all-in-one housing installs in 4 rack spaces (4U). Upright tower and two post rackmount installation supported with optional accessories. Maintains full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V (L-N). Expandable runtime with optional external battery packs. Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination DB9 RS-232 enabled and dry contact serial port, enhanced USB port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Split phase 4 conductor hardwire input. UPS supported outlets include two L6-30R, two L6-20R and 4 low voltage 5-15/20R. Hardwire output is also supported. Hardwire connections and outlets are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment. Internal batteries and optional external battery packs are field replaceable and hot swappable. Attractive all-black color scheme. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).- True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise- 8000VA/5600 watt output power capacity with dual voltage output of 208/120 or 240/120V- 4U all-in-one high power density housing supports rackmount installation in only 4 rack spaces- Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types- Hardwire input/output connections and output receptacles are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment- Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical servers, networking and telecommunications equipment- Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages- Supports connected equipment during blackouts for 12/5 minutes at half/full load levels, runtime is further expandable with optional external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP- Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control- Built-in Emergency Power Off (EPO) interface with cable- Includes hardwire output and 8 output receptacles (2 L6-30R, 2 L6-20R, 4 NEMA 5-15/20R), all of which are available for simultaneous use- Split phase, 4 conductor hardwire connection (featured on included detachable PDU).- Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions- Front panel switches enable power on/off control, self-test and alarm cancel functions- Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures- Optional 2-9USTAND set of tower stands supports upright tower installation- Optional 2POSTRMKITHD accessory enables 2 post rackmount installation- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Tripp Lite's SM3000RMXL2UTAA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases. 3000VA / 3kVA 120V line interactive 2U rack / tower UPS offers complete network-grade power protection with full support for hot-replacement of separate internal battery and electronics modules. High .96 power factor supports loads up to 2880 watts. High efficiency rating of 96% reduces electrical operating cost and BTU emissions. Supports 120V 60Hz operation. Maintains battery derived sine wave AC output during power failures. Line-interactive dual-boost, single cut automatic voltage regulation (AVR) provides regulated 120V nominal output during brownouts and overvoltages. Includes NEMA L5-30P input plug and 9 UPS-supported output receptacles (8 x 5-15/20R, 1 x L5-30R). Includes two individually controllable switched outlets for advanced remote-reboot and load-shedding applications. Network-grade AC surge and noise suppression. Network management interfaces support simultaneous communications via USB, DB9 serial and card slot for optional SNMPWEBCARD and other card accessories. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via all three network interfaces at once. Advanced LED indicators offer 3-stage metering of UPS load and battery charge levels, plus single-LED status indicators for utility power, voltage regulation, on-battery and replace battery. Audible alarms provide notification of on-battery, low-battery and overload conditions. Includes PowerAlert auto-shutdown and management software for complete monitoring, reporting and logging of all site and UPS operational conditions, plus support for advanced configurations involving load-shedding, remote-reboot and redundant dual-UPS applications. Internal batteries offer runtime of 10 minutes half load (1440 watts) and 3 minutes at full load (2880 watts). Runtime is expandable with optional BP48V24-2U (limit 1) and BP48V60RT3U (unlimited) external battery packs. Supports installation in 4 post racks with included accessories. 2 post rackmount, wallmount and tower stand accessories sold separate. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Tripp Lite SU20KRTHW 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU20KRTHW 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input (3 wire) and hardwire output (3 wire) connectionsSupports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / outputOptional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurationsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteriesIntelligent battery management system with temperature-compensated charging extends battery lifeUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
3000VA / 3kVA online, double-conversion UPS system in 3U rackmount form factor for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 29.5 inches (75cm). Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Hardwired AC input and output (L-N-G, 120V). Highly efficient operation in optional economy mode setting, saves BTU heat output and energy costs. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Multi-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for better viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network ethernet connection. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. 4 post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITHD 2-post rackmount accessories available. Field replaceable, hot swappable internal batteries and external battery packs. Attractive all-black UPS design. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).- 3000VA / 3kVA / 2400 watt online, double-conversion UPS system in 3U rackmount form factor for critical server, network and telecommunications equipment- True online, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values- Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs- Internal battery set offers 30 minutes runtime at half load (1200W) and 12 minutes at full load (2400W)- Optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches- Ships with all mounting accessories for 4 post rackmount installation- Optional 2POSTRMKITHD enables 2 post rackmount installation- Optional 2-9USTAND accessory enables small-footprint upright tower placement- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Network interfaces support simultaneous communications via built-in USB, DB9 serial/contact-closure and SNMPWEBCARD slot- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints- Built-in Emergency Power Off (EPO) interface with cable- Hardwire 120V AC input/output (L-N-G)- Front panel LEDs offer current monitoring and battery charge level information- Single line TEL/DSL or network ethernet line surge suppression- $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA