Battery Backup and VFI Operation Protect Critical LoadsThe SmartOnline® S3M80KXD IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 80kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and edge infrastructure environments.Best-in-Class Footprint for Easy Integration into Your Network ApplicationThis on-line double-conversion UPS system has a very small footprint of just 0.28 square meters. It requires less valuable space in your facility, and you can install the UPS system in spaces that would previously have required expensive retrofitting.Efficient Operation and Design Reduces Cost of OwnershipThis UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (
The SV20KM1P0B SmartOnline® SV Series 20kVA 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system is ideal for protecting a variety of critical IT systems.The SV20KM1P0B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS) and one 20kVA SV20PM power module. Space is included for up to three additional user-installable SV20PM power modules. External ±120VDC battery options, such as BP240V370 or EBP240VXXX series batteries cabinets are available from Tripp Lite for extended runtime.The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 20kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.20kVA 18kW 3-Phase Medium-Chassis UPS System- Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring- Dual hardwire input design enables operation from up to 2 power sources- Network-grade sine-wave AC output with 1% output voltage regulation and less than 1% output total harmonic distortion- Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards- High 0.9 power factor for maximum power to the connected loadPre-Installed WEBCARDLX Network Interface- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status- No Java requiredModular, Scalable Design for Maximum Flexibility- Modular configuration with hot-swappable power modules and batteries enables easy, fast maintenance with zero downtime- Open slots for up to 3 additional 20kVA SV20PM power modules accommodate increased capacity up to 80kVA (or 60kVA with N+1 fault tolerance)- Supports external ±120VDC battery options for extended runtimesOptional Economy Mode- Up to 99% efficient in optional economy mode to lower operating and cooling costsWide Input/Narrow Output Voltage Operating Range- Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V- Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion modeAdvanced IGBT Inverter with Digital Signal Processor (DSP) Technology- Provides for less than 2% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacityAutomatic and Manual Bypass Options- Keep connected equipment operational during routine maintenance or critical power module failurePackage Includes- SV20KM1P0B SmartOnline SV Series 20kVA 3-Phase On-Line Double-Conversion UPS System- Pre-installed WEBCARDLX network interface- (1) SV20PM 20kVA power module (shipped separately)- Owner’s manual
The SV60KS3P0B SmartOnline® SV Series 60kVA Small-Frame 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system with a high 0.9 power factor is ideal for protecting a variety of critical IT systems.The SV60KS3P0B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS) and three 20kVA SV20PM power modules. It comes fully configured for 60kVA total capacity or 40kVA with enhanced N+1 protection. External ±120VDC battery options, such as BP240V370 or EBP240VXXX series battery cabinets, are available from Tripp Lite for extended runtime.The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.With up to 92% efficiency in standard mode and up to 98% efficiency in optional economy mode, this 60kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.60kVA 54kW 3-Phase Small-Chassis UPS System- Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring- Dual hardwire input design enables operation from up to 2 power sources- Network-grade sine-wave AC output with 1% output voltage regulation and less than 2% output total harmonic distortion- Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards- High 0.9 power factor offers higher kW output than lower-rated competing legacy designsPre-Installed WEBCARDLX Network Interface- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status- No Java requiredModular, Scalable Design for Maximum Flexibility- Modular configuration with hot-swappable power and battery modules enables easy, fast maintenance with zero downtime- Comes fully configured for 60kVA total capacity or 40kVA with N+1 fault tolerance- Supports external ±120VDC battery options for extended runtimesOptional Economy Mode- Up to 98% efficiency in optional economy mode to lower operating and cooling costsWide Input/Narrow Output Voltage Operating Range- Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V- Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion modeAdvanced IGBT Inverter with Digital Signal Processor (DSP) Technology- Provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacityAutomatic and Manual Bypass Options- Keep connected equipment operational during routine maintenance or critical power module failurePackage Includes- SV60KS3P0B SmartOnline SV Series 60kVA Small-Frame 3-Phase On-Line Double-Conversion UPS System- Pre-installed WEBCARDLX network interface- (3) SV20PM 20kVA power modules (shipped separately)- Owner’s manual
10kW 3-Phase PDU Distributes and Monitors Network-Grade PowerThis monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the PDU3EVNR6L2130 features 24 C13 and six C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged.Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real TimeNot only can you remotely monitor voltage and frequency, but the PDU3EVNR6L2130 also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.Built-In LX Platform Network Management Card Allows Remote Access 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP.Color Touchscreen LCD Gives You Important Data at a GlanceAn easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a NEMA L21-30P 208/240V input connects the PDU to a compatible AC power source, generator or protected UPS.TAA-Compliant for GSA Schedule PurchasesThe PDU3EVNR6L2130 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
14.5kW 3-Phase PDU Distributes and Monitors Network-Grade PowerThis monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Built-In LX Platform Network Management Card Allows Remote Access 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.Color Touchscreen LCD Offers Important Data at a GlanceAn easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with Hubbell CS8365C 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.TAA-Compliant for GSA Schedule PurchasesThe PDU3EVN6H50BA is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.Typical Applications- Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility- Monitor power loads from various computers, switches, servers and other networking equipmentPackage Includes- PDU3EVN6H50BA 14.5kW 3-Phase Monitored PDU- Built-in LX Platform interface- Configuration cable- (42) Plug-lock insert sleeves- Rack-mounting hardware- Spare mounting buttons- PDUMVROTATEBRKT mounting bracket accessory- Owner’s manual
Bypass an SUT60K UPS to Perform MaintenanceFor use with Tripp Lite’s SUT60K 3-phase UPS system, the SUT60KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel’s trim cover to be removed for internal access. Maximum current capacity is 225A.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).One-Year WarrantyThe SUT60KMBP is backed by a one-year limited warranty, ensuring reliability and performance.
Extend the Runtime of SV-Series UPS SystemsTripp Lite’s BP240V370 external backup battery pack extends runtime for SV-Series UPS systems. It consists of a battery cabinet and sealed lead acid batteries. Up to three external battery pack cabinets may be connected in parallel to increase runtime.Enjoy Compatibility with SV-Series UPS SystemsThe BP240V370 external UPS battery pack uses a +/- 120V DC configuration and must be hardwired to a compatible UPS. Circuit breakers provide overcurrent protection. The BP240V370 is compatible with Tripp Lite UPS models that begin with SV20, SV40, SV60, SV80, SV100, SV120 and SV140.Maintain a Uniform Look in Network EnvironmentsMade of powder-coated steel, the battery cabinet is designed to match the SV-Series UPS systems to keep a consistent look in your server room or data center. The cabinet door is lockable to control access to batteries. The top of the cabinet has conduit knockouts for user-supplied power output cables. Front and rear vents allow the free flow of warm air out of the cabinet, and appropriate spacing providesventilation between individual batteries.Comply with TAA RequirementsThe BP240V370 complies with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.One-Year WarrantyThe BP240V370 is backed by a one-year limited warranty, ensuring reliability and performance
Tripp Lite EBP240V5001. Form factor: Tower, Product color: Black, Housing material: Steel. Battery technology: Sealed Lead Acid (VRLA), Battery voltage: 120 V. Certification: TAA, UL 1778 CSA C22.2 NO. 107.1, CSA, CE EN 62040-1-2:2003, EN 60950-1. Width: 29" (736.6 mm), Depth: 31.5" (800.1 mm), Height: 59" (1498.6 mm). Country of origin: Taiwan, Master (outer) case width: 29" (736.6 mm), Master (outer) case length: 31.5" (800.1 mm)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA