"APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within serverand/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level powermetering for power visibility and notification of potential overload. 4-in-1 combination outlets which canbe used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximumoutlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/orlabeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternatingphase design whereby each of the 3 phases are organized into small outlet groups which alternatefrom top to bottom of the PDU to facilitate better power cord management and promote better loadbalancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an NetworkManagement Card to continue functioning in the event of an AC power loss. No interruption in Networkcommunication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC)which can be replaced without powering down the PDU or connected devices to minimize downtimein the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at fullload ensures reliability and availability even in today's high density deployments. Gigabit ethernet toenhance and standardize network connectivity across all assets in the data center. A second ethernetport (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, orprovide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDUAdvanced to bill based on power usage. In addition, the higher level of accuracy ensures the mostprecise measures for capacity planning and threshold alarm monitoring. Two environmental sensorports allow for optional sensors (sold separately) to be connected. For data center deployments acrossmultiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally tosimplify and standardize deployment."
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
FeaturesAPC SurgeArrest Essential Multi-Use 6 Outlet with 2 Type-A 1 Type-C Port 4.8A USB Charger 120VBasic Protection Against Power Surges for Computers and ElectronicsCatastrophic Event ProtectionSurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.EMI and RFI noise filteringReduces line noise that can cause data loss and keyboard errors.Fail Safe ModeMost other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.IEEE let-through ratings and regulatory agency complianceAPC surge protectors undergo stringent testing by IEEE, and are awarded "let-through ratings", which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V to 500V for North American products, and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements, including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.Lightning and Surge ProtectionTo prevent damage to your equipment from electric power surges and spikes.Noise FilteringAttenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment.Protection Working IndicatorSurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.Right Angle PlugPlug angle allows for equipment and furniture to be placed closer to the wall than with a standard power cord. Reduces cord stress too.Smart charging portA 2.4 amp USB port integrates Smart Charging technology to maximize charging speeds according to the type of device detected.USB charging portsSimultaneously charge mobile devices, including smartphones and tablets.Noise FilteringAttenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment.IEEE let-through ratings and regulatory agency complianceAPC surge protectors undergo stringent testing by IEEE, and are awarded "let-through ratings", which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V to 500V for North American products, and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements, including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.Lightning and Surge ProtectionTo prevent damage to your equipment from electric power surges and spikes.Lightning and Surge ProtectionTo prevent damage to your equipment from electric power surges and spikes.Data-line ProtectionProtection of data lines (Ethernet, Coaxial and Phone lines) ensures complete protection of your equipment from surges. It is very important to protect your equipment from “back door” electric surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines.Protection Working IndicatorSurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)Fail Safe ModeMost other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.Catastrophic Event ProtectionSurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.Building Wiring Fault IndicatorThis LED informs users of potentially dangerous wiring problems in the wall circuit.Protection Working IndicatorSurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.Fail Safe ModeMost other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.
APC Basic Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 32A 3P+N+PE , Cord Length: 6 feet ( 1.83 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19Includes: Installation guide, Toolless Mounting Kit.
Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
APC Rack PDU 9000 Switched, ZeroU, 17.2kW, 208V, (20) C13, (12) C19
InfraStruxure PDU, 150kVA, 416A, 480V:208V Isolation Transformer, 84 Poles, 1 SubfeedAPC Configurable Power Distribution, Input: 480V 3PH, Output: 208V 3PHIncludes: Installation guide, Network Management Card
A fully scalable power distribution system that cost-effectively provides high levels of availability and enables the addition of circuits and cord-sets without requiring you to schedule outages or conduct dangerous hot work.UL-listed Touch-safe backplaneAdding Power Distribution Modules requires no hot work; one trained user can safely add new modules without removing power to the existing PDU load
Field-replaceable NMCIntegrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.High Retention OutletsWith no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.60C Operating TemperatureSelect 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).C13/C15 and C19/C21 Hybrid OutletsAvailable on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.
With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on/off outlet level power cycling and sequencing control.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA