Introducing the redesigned APC NetShelter SX rack enclosure - trusted, versatile, and built for demanding IT environments. With larger load capacities and more space for equipment, it enables higher-density computing. Choose from standard, wide, extra wide, and large-depth options. The modern look is perfect for colocation and customer-facing businesses. Simplify workflows with easy access to cabling and equipment, and optimize airflow and cable management with our wide range of APC accessories. The 270° (180° bayed) opening doors keep aisles clear, while 80% door perforation improves airflow for high-powered servers. Built sustainably with all-steel construction, it lasts for years and can be used for various applications. It also boasts a 3.3% decarbonization rate and ships in sturdy, recyclable packaging.
NetShelter CX 24U in colour Dark Grey- Acoustic foam lining for noise dampeningSuperior noise reduction of installed IT equipment allowing the enclosure to be placed in a quiet environment.- Adjustable Front Vertical Mounting RailThe front mounting rails can be adjusted to allow for various mounting depths and to allow for additional clearance from the front door.- Dedicated rear cable access pointThe cable port has a capacity of up to 400 cables and is situated perfectly for ground or under-floor cabling.- Four vertical 0U accessory channelsProvides multiple mounting locations for cable management accessories and rack PDUs without using critical equipment space.- Integrated heat removalHigh efficiency fan modules remove heat and eliminate the need to purchase a costly cooling unit for your IT equipment.- Integrated power distributionProvided with a rack power distribution unit servers and other equipment are ready for deployment.- Lockable front doorsProtect IT equipment from unwanted access- Removable side panelsProvides customers with easy accessibility to equipment.Agility- Acoustic foam lining for noise dampeningSuperior noise reduction of installed IT equipment allowing the enclosure to be placed in a quiet environment.- Light oak veneer finishThe enclosure blends discretely into almost any office environment.- Lockable front doorsProtect IT equipment from unwanted access- Toolless Rack Mounting CapabilitiesServer cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.- Plug and Play setupFast and Easy set up
The NetBotz Rack Access Pod 1356 Kit provides remote rack access monitoring and control and 13.56 MHz badge access for IT environments when paired with NetBotz appliance or NBPD0175 Rack Access Pod The NetBtoz Rack Access 1356 enables rack access control using 13.56 MHz proximity cards or remote access control through EcoStruxure IT Software Get instant alerts for access control risks such as breached enclosures or enclosures left open Up to 26 handles can be controlled on one NetBotz 750 appliance when paired with NetBotz 175 Rack Access Pods Kit includes 2 rack access control handles for front and rear applications on a single enclosure.
APC NetShelter SX 52U White
Rapidly deployable, self-contained row-based cooling solutions for server rooms and wiring closets. -Includes: Exhaust duct kit, Installation guide, Operations and maintenance manual.-Active response controls. -Dry contact output. -Easy to install. -Fault-tolerant fan system. -Field replaceable components. -Horizontal airflow pattern. -Individual hot swappable fans. -LED status indicators. -Network interface. -Predictable cooling. -Remote management. -Scalable architecture. -User replaceable fans.
Facilitates front cable management while allowing cables to pass through to rear appliances Occupies 2U of rack space
Electric ReheatPrevents overcooling during dehumidification.HumidifierHumidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.InRow Chilled Water CoolingFeatures & BenefitsManageabilityBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.Real-Time Capacity MonitoringReal-time display of current and available cooling.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Total Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.AvailabilityActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Rack inlet controlRack inlet control guarantees inlet temperature to IT equipment.Top and bottom chilled water connectionsAllows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Dual A-B power inputsDraws power from the UPS for power protection with dual feeds for redundancy.AgilityCastersProvides flexibility to move the unit to wherever cooling is required.Scaleable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Modular designModular design provides scalable solutions to add cooling as demand increases.ServiceabilityEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Total Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.AvailabilityActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Top and bottom chilled water connectionsAllows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.Rack inlet controlRack inlet control guarantees inlet temperature to IT equipment.Dual A-B power inputsDraws power from the UPS for power protection with dual feeds for redundancy.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.ManageabilityBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Real-Time Capacity MonitoringReal-time display of current and available cooling.AgilityCastersProvides flexibility to move the unit to wherever cooling is required.Scaleable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Modular designModular design provides scalable solutions to add cooling as demand increases.
Snap-on hinge covers conceal cables for a clean, professional look and easy access
Universal Sensor that monitors access to NetShelter SX Enclosures. Manage intentional or accidential access events that could pose a significant threat to the company's IT infrastructure Compatible with all current and legacy generation NetBotz appliances and pods includes 12 ft of cable length for flexible installation applications. Suitable for applications where only one door sensor is required
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA