Hot and cold air containment systems designed to maximize cooling predictability, capacity, and efficiency at the rack, row or room level.
APC ACDC2307 rack accessory Blank panel
APC ACDC2311 rack accessory Cable duct
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centersUniflair Direct Expansion InRow Cooling Features & BenefitsPredictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Rack inlet temperature controlReduces the risk of hot spots at the rack levelModular designModular design provides scalable solutions to add cooling as demand increases.Scalable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Real-Time capacity monitoringReal-time display of current and available cooling.Microprocessor controllerUtilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric displayBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centersPredictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Rack inlet temperature controlReduces the risk of hot spots at the rack levelModular designModular design provides scalable solutions to add cooling as demand increases.Scalable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Real-Time capacity monitoringReal-time display of current and available cooling.Microprocessor controllerUtilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric displayBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
APC SCHNEIDER INROW DX 300MM 30KW INDOOR 200-240V HUM RH CE/UL
APC ACDC2551 rack accessory Depth adapter
The APC NetShelter 2 Post Rack is a 45U open frame rack designed for easy access to IT equipment and cabling. The rack conforms to EIA-310E standards, ensuring compatibility with a wide range of IT equipment. It includes 24 12-24 pilot screws of 0.5 inch and a user manual for easy installation.
The NetBotz Rack Access Pod 125 Kit provides remote rack access monitoring and control and 125 kHz badge access for IT environments with two or more enclosures The NetBotz Rack Access Pod 125 Kit simplifies configuration of rack access solutiosn by includes (1) NetBotz 175 Rack Access Pod (1) NetBotz 125 pair of 125kHz handle kits and (1) NBES0303 pair of door switch sensors Connect up to 12 rack access pods together to provide rack access control monitoring and instant alerts for up to 24 doors The NetBotz Rack Acces Pod 125 Kit is only available for use with NetBotz 750 Rack Monitor Appliance or NetBotz 755 Room Monitor Appliance. Get instant alerts for access control risks such as breached enclosures or enclosures left open Pair with AP370-10 HID Proximity Cards for addition 10 rack access users
Rack components that can be added to existing racks if requirements change.