A high-efficiency 3-phase UPS that is scaleable as your data center grows up to 40KW/40KVA. Suitable for small to medium data center application. -Fully-rated power kW equals kVA -Hot-swappable modules -User-replaceable modules -Warranty: 1 year repair or replace
Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model
Symmetra® LX High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks. Symmetra LX -6400 Watts. -8000 VA. -Input 208V. -Output 120V, 208V. -Interface Port DB-9 RS-232. -Smart-Slot. -Extended runtime model.
High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks.
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceModular designIncreases adaptability with an open architecture configurable to any IT environment.Modular designModular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedBattery modules connected in parallelDelivers higher availability through redundant batteries.Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.Locking cabinetPrevents unauthorized access to the UPS.Modular designModular design provides scalable solutions to add cooling as demand increases.Battery replacement without toolsAllows quick, easy battery replacement.Front-access servicingSimplifies installation and maintenance while minimizing space requirements.
APC Symmetra RM 8-12kVA Battery Module Features - Hot Pluggable Operation, Hot Swap Batteries
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures. Battery modules connected in parallel Delivers higher availability through redundant batteries. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Automatic restart of loads after UPS shutdown.
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures. Battery modules connected in parallel Delivers higher availability through redundant batteries. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Automatic restart of loads after UPS shutdown.
APC Symmetra PX 100
Accessories for high-performance, right-sized, modular, scalable 3 phase UPS (10-100kW 208V, 100-500kW 480V, 16-500kW 400V) for any size data center or facility.