AgilityRack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A, 208V, (21) C13 & (3) C19APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.Includes : CAN Port Terminator , Installation guide , Locking input power cord , Rack Mounting brackets , Safety guide , Serial configuration cableMetering-by-Outlet capabilityIndividual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.Availability- Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).- Metering-by-Outlet capabilityIndividual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.- Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)- Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.- Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)- Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)- Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)- Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.- Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkAgility- Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Rack PDU 2G, Metered, ZeroU, 20A, 120/208V 3Ph, (24) 5-20R (6) L6-20RAPC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
Card chassis provides additional SmartSlots for APC UPSs. Features: Computer Interface Cable, Multiple Application Configuration, Optional Power Supply, Rack Mount, UPS Accessory Expansion, UPS Management Peripheral Chassis Includes - Mounting pads, User Manual
This product is EOL and replaced by the AP9614The Dry Contact I/O Card provides 6 configurable output relays and 4 input contacts to monitor external triggers and initiate actions on external devices. The 2 Universal I/O (UIO) ports support optional environmental sensors and the Dry Contact I/O Accessory. The Dry Contact I/O Accessory provides 2 additional dry contact input and relay output interfaces. Connect the included USB cable to the Card and a PC to use the Configuration Utility user interface. Configure UPS settings and output relay, input contact and environmental sensor actions based on status changes or UPS events.
Cage nuts with #10-32 thread for mounting equipment in enclosure for square mounting rails Accommodates devices using #10-32 mounting screws (Qty 36)
This product is part of the Back-UPS range. The BK550EI features a total of 6 power outlets, 3 of which are UPS battery backup and 3 that are surge only. Its runtime at 100W is 24 minutes 20 seconds It provides data line protection with a RJ45 analog phone line for phone or fax or modem or DSL. Its dimensions are 16.5 x 9.1 x 28.4 cm and 6.32kg. The BK550EI ensures office systems and their valuable data are protected from dangerous power surges, spikes and blackouts.
APC Symmetra PX, 20 kW / 20 kVA, Input 208V 3PH / Output 120V, 208V, 208V 3PH , Interface Port Smart-Slot , Extended runtime model , Rack Height 42 U Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures. Battery modules connected in parallel Delivers higher availability through redundant batteries. Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Network manageable Provides remote management of the UPS over the network. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable power capacity Reduces UPS over-sizing costs today by allowing quick upgrades later. Scalable runtime Allows additional run time to be quickly added as needed. Front-access servicing Simplifies installation and maintenance while minimizing space requirements. Programmable frequency Ensures compatibility with different input frequencies. SmartSlot Customize UPS capabilities with management cards. Battery replacement without tools Allows quick, easy battery replacement. Fully-rated power kVA equals kW Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads. Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. 5x8 Start-up service included Required for full coverage of factory warranty InfraStruXure Central compatible Enables centralized management via StruxureWare Central. LED status indicators Quickly understand unit and power status with visual indicators. Audible alarms Provides notification of changing utility power and UPS conditions
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.High online efficiencyReduces utlility costs, generates less heat.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.