Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.
APC Maintenance Bypass Panels , Input: 120V , Input Connections: NEMA L5-30P , Cord Length: 8 feet ( 2.44 meters ) , Output: 120V , Output Connections: NEMA 5-20R,NEMA L5-30RQuick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical load
The PDUMH15NET2LX 1.4kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.The 1U PDU features eight switched NEMA 5-15R outlets with an included cord retention bracket to prevent cables from becoming accidentally disconnected. A 12-foot cord with NEMA 5-15P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor the total load in real time to ensure it remains well below maximum capacity with no danger of overload. The rack-mount PDU installs in 1U of space in EIA-standard 19-inch racks. You can also mount it vertically in 0U of rack space or on a wall or under a counter with the included brackets and user-supplied screws.Distributes, Monitors and Manages Network-Grade AC Power- 1.4kW 120V switched PDU with single-phase input- Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components- NEMA 5-15P plug with 12 ft. cord connects to compatible AC power source- Firmware upgrades support future product enhancements- Digital ammeter reports total PDU load in real time8 Switched NEMA 5-15R Outlets Distribute AC Power- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices- Cord retention bracket prevents cables from becoming accidentally disconnected- Individual LEDs indicate which outlets are liveBuilt-In LX Platform Interface- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications Compatibility- Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP- Supports automatic and manual assignment of IP addressEssential Safety Features- Immediate alert notifications via email or SNMP traps- Supports user-specified alarm notification thresholds- Real-time clock backup maintains day/date even if PDU is unpoweredFlexible Mounting Options- Included rack-mounting brackets compatible with front- or rear-facing installation- Compatible with 1U horizontal, 0U vertical, wall and under-counter mounting with included brackets and user-supplied screwsTAA-Compliant- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Rack PDU 2G, Metered, ZeroU, 20A, 100-120V, (24) 5-20RAPC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cableLocal Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Local and web-based monitoringStatus available to customers both in the data center and remotelyAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
"APC Basic Rack 1.92kVA. Product color: Black. Input connection type: NEMA L5-20P, Output connections: (24) NEMA 5-20R. Cable length: 120.1"" (3.05 m), Certification: cUL,CSA C22.2 No. 60950-1-03,UL 60950-1,UL. Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Dimensions (WxDxH): 2.2 x 1.73 x 63.7"" (56 x 44 x 1619 mm), Weight: 10.7 lbs (4.86 kg)"
Add eight power outlets from a single power outlet in 1U of rack spaceThis 1U 8-Outlet Rack Mount Horizontal PDU features a built-in 8ft. (2.4m) NEMA 5-15P power cord and 8x NEMA 5-15R outlets, delivering 125V maximum input/output. With a 15A circuit breaker, this unit ensures the protection and stable operation of your critical equipment.Individual On/Off Outlet SwitchesEach outlet on the PDU is equipped with an independent/individual illuminated rocker switch, allowing for precise power management and control. The clearly enumerated switch labels make it easy to identify the switch to manage each connected device. Safety covers on the switches prevent accidental power cycling, adding an extra layer of security to the setup. This feature is particularly valuable in environments where uptime and equipment protection are paramount.15A circuit BreakerThe 1U 8-Outlet Rack Mount PDU features a robust 15 amp circuit breaker, designed to provide unparalleled protection for your connected equipment. This self-tripping and resettable breaker ensures that in the event of an overload or electrical fault, power is immediately cut off to prevent damage to your valuable devices. The 15A trip-point is precisely calibrated to handle the power demands of server rooms, data centers, and other professional IT environments, offering peace of mind and reliable operation. By swiftly interrupting the power supply in adverse conditions, this circuit breaker not only safeguards your equipment but also minimizes downtime and maintenance efforts, making it an essential component for any high-performance power distribution setup.1U Rack Mount DesignEngineered for compatibility, the 1U rack design easily installs into any 19-inch server rack that is four inches or deeper, utilizing just 1U of rack space. Adhering to ANSI/EIA RS-310-D standards, this horizontal-mount PDU is a perfect fit for any network rack, ensuring a streamlined and organized power distribution system.The PDU features an optimized design with heavy-duty steel housing and rear-facing outlets, maximizing space efficiency and durability, making it a reliable addition to any professional IT environment. Additionally, the attached 8 ft. (2.4m) power cord provides the flexibility and reach needed to accommodate various rack configurations, simplifying the setup process.The StarTech.com Advantage
"Tripp Lite PDU121506. PDU types: Basic, Rack capacity: 0U/1U, Type: Single-phase. AC outlets quantity: 13 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Cable length: 72"" (1.83 m). Nominal input voltage: 100 - 127 V, Maximum current: 15 A, AC input frequency: 50 - 60 Hz. Width: 20"" (508 mm), Depth: 4.5"" (114.3 mm), Height: 1.75"" (44.4 mm)"
AP7902BFeaturesRack PDU, Switched, 2U, 30A, 120V, (16)5-20Resettable circuit breakersEnables a quick recovery from overload events.AgilitySingle input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Marketing FeaturesLocal Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).AvailabilityAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkNetwork Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
"Tripp Lite PDUV30. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-30P. Cable length: 120.1"" (3.05 m). Nominal input voltage: 100 - 127 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.19"" (55.6 mm), Depth: 3.75"" (95.2 mm), Height: 63.7"" (1619.2 mm)"
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA