Catastrophic Event ProtectionSurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.EMI and RFI noise filteringReduces line noise that can cause data loss and keyboard errors.Fail Safe ModeMost other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.IEEE let-through ratings and regulatory agency complianceAPC surge protectors undergo stringent testing by IEEE, and are awarded "let-through ratings", which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V to 500V for North American products, and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements, including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.Lightning and Surge ProtectionTo prevent damage to your equipment from electric power surges and spikes.Noise FilteringAttenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment.Protection Working IndicatorSurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.Right Angle PlugPlug angle allows for equipment and furniture to be placed closer to the wall than with a standard power cord. Reduces cord stress too.
6.6kW 3-Phase 0U PDU Distributes and Monitors Network-Grade PowerThis monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6L1520 features 42 C13 and six C19 208/240V outlets in three load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Built-In LX Platform Network Management Card Allows Remote Access 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.Color Touchscreen LCD Offers Important Data at a GlanceAn easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. A six-foot cord with NEMA L15-20P 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.TAA-Compliant for GSA Schedule PurchasesThe PDU3EVN6L1520 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.Typical Applications- Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility- Monitor power loads from various computers, switches, servers and other networking equipmentPackage Includes- PDU3EVN6L1520 6.6kW 3-Phase Monitored PDU- Built-in LX Platform interface- Configuration cable- (48) Plug-lock insert sleeves- Rack-mounting hardware- Spare mounting buttons- Owner’s manual
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loadsPDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option2U horizontal rackmount form factor compatible with 2 or 4 post racksSupports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported)8 C13 outlets support critical networking loads in both Utility and UPS operating modesOne additional C13 pass-through outlet supports UPS input power cordDual input power cables support PDU connection to separate Utility and UPS power sourcesManual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPSSet the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPSSet the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh oneOnce the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
11.5kW Switched 360-415V input 208-240V output PDU with built-in web/network interfaceIEC309 16/20A Red (3P+N+E) 360-415V 3 phase input with 6 ft. / 1.8m line cord0U, 70 inch / 178cm vertical form factor30 switched 208-240V outlets (24 C13, 6 C19) in 3 single phase load banksSupports power-on, power-off or reboot of each outlet on a real-time or programmable basisEnables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outletsNetwork interface provides PDU control and data regarding input voltage and load levels per-outlet and per-phaseBuilt-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientationSupports user-specified alarm notification thresholdsDHCP/Manual configuration support10/100 Mbps auto-sensingReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browserAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancementsSupports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocolsFully compatible with FREE PowerAlert Network Management System / NMS SoftwareIncluded set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outletsToolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Accessories to upgrade and expand your installed APC power distribution units.
11.5kW Monitored 360-415V input 208-240V output PDU with built-in web/network interfaceIEC309 16/20A Red (3P+N+E) 360-415V 3 phase input with 6 ft. / 1.8m line cord0U, 70 inch / 178cm vertical form factor48 208-240V outlets (42 C13, 6 C19) in 3 single phase load banksLighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feedsBuilt-in SNMP/ethernet interface reports voltage and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholdsSupports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensorsDHCP/Manual configuration support 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browser for monitoringAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancementsSupports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocolsFully compatible with FREE PowerAlert Network Management System / NMS SoftwareIncluded set of plug-lock inserts keep C14 & C20 power cords solidly connected to PDU outlets Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included) Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Vertiv Monitored rack PDUs (rPDU) provide a comprehensive view of power usage, both at the rack and via remote access while continuing to provide reliable power distribution to critical IT equipment. Monitored rPDUs are available in a variety of electrical and receptacle configurations. Every unit is 100% tested for reliability and functionality.