Tripp Lite PDU3V20D354B. PDU types: Basic, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 54 AC outlet(s), AC outlet types: C13 coupler, C19 coupler. Cable length: 29.9" (0.76 m). Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz. Compliance certificates: RoHS, Certification: Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS
Eaton EATON RATED OUTPUT LUGS PDU BYPASS W/FULL
The PDU3V51 8.6/12.6kW 3-Phase Vertical PDU Outlet Strip is a required accessory for Tripp Lite’s PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other 3-phase ATS PDUs that specify compatibility with this model. It’s ideal for high-density equipment racks in data centers and server rooms.When used with 208V ATS PDUs with a 35A input rating, the PDU3V51 supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank (L1-L2, L2-L3, L3-L1). When used with 208V ATS PDUs with a 24A input rating, it supports up to 8.6kW total output with 13.9A maximum full balanced load per phase combination output bank.The 51 single-phase 12A C13 outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers them. The 2.5-foot power cord with eight-position plug connects directly to the ATS PDU’s rear outlet.The PDU3V51’s rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cable clutter and improves airflow through the rack to keep your equipment cool and functioning at its peak. Required Accessory for Select Tripp Lite ATS PDUs- Compatible with PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other select Tripp Lite 3-phase ATS PDUs- Ideal for high-density equipment racks in data centers and server rooms- Supports up to 12.6kW total output with 20A maximum per output bank when connected to 208V ATS PDUs with a 35A input rating- Supports up to 8.6kW total output with 13.9A maximum per output bank when connected to 208V ATS PDUs with a 24A input rating51 Interlaced C13 Outlets- Single-phase 12A C13 outlets balance loads by spreading connections across all phase combinations throughout the rack- Numbered and color-coded for easy identification of connected devices and which phase combination output bank powers themInstalls Easily in 0U of Rack Space- Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks- Reduces cable clutter by locating outlets closer to connected devices- Improves airflow through the rack to keep equipment cool and functioning at its peak- Rugged all-metal housing designed to last a long time- 2.5 ft. power cord with 8-position plug that connects directly to ATS PDU
Eaton EATON PDU WITH BYPASS W/ 3 SUBFEED BREAKERS
Eaton EATON PDU WITH BYPASS W/ 2 SUBFEED BREAKERS
Eaton EATON PDU EPO 2U IN: 5-20P 16A 1P OUT: 12X5-20
Eaton EATON PDU EPO 1U IN: L5-20 12A 1P OUT: 10X5-15
APC Switched Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E , Cord Length: 6 feet ( 1.83 meters ) , Output: 208V, 230V , Output Connections: IEC 320 C13,IEC 320 C19.Includes: Installation guide, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable.
Eaton PDU with bypass w/ 1 42 pole panelboard, full rated output lugs
Eaton EATON RACK ASSY 2686
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA