AgilityWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Total Cost of OwnershipLow Cost Power DistributionProvides a number of outlets to bring power to rack equipment at an affordable price.Marketing FeaturesWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Low Cost Power DistributionProvides a number of outlets to bring power to rack equipment at an affordable price.
1.9kW vertical PDU with individual outlet metering distributes, monitors and manages single-phase power. Built-in Java-free network interface helps you remotely monitor load levels to prevent overloads that cause downtime.The PDUMVR20NETLX 1.9kW Single-Phase Switched PDU with individual outlet metering provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.The switched PDU features 24 individually controllable NEMA 5-15/20R outlets with cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot power cord with NEMA L5-20P plug and optional 5-20P adapter connects the PDU to an AC source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor each load bank’s current, each outlet’s current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The switched PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.Distributes, Monitors and Manages Network-Grade AC Power- 1.9kW 120V 20A switched PDU with single-phase input- 10 ft. power cord with NEMA L5-20P plug and 5-20P adapter- Firmware upgrades support future product enhancements24 NEMA 5-15/20R Switched Outlets Distribute AC Power- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices- Included cord retention brackets prevent cables from becoming accidentally disconnectedDigital Ammeter- Reports current for each load bank, each individual outlet, and total PDU load- Supports IP-address self-ID- Digits flip 180° for easy reading at either angleBuilt-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications Compatibility- Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP- Supports automatic and manual assignment of IP addressEssential Safety Features- Tiered access allows administrator and guest to log in via web browser- Immediate alert notifications via email or SNMP traps- Supports user-specified alarm notification thresholds- Real-time clock backup maintains day/date even if PDU is unpoweredEasy 0U Installation in EIA-Standard 19 in. Racks- 70 in. PDU mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
APC Basic Rack 2880VA. Product color: Black. Input connection type: NEMA L5-30P, Output connections: (24) NEMA 5-20R. Cable length: 120.1" (3.05 m). Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Certification: cUL,CSA C22.2 No. 60950-1-03,UL 60950-1,UL
The APC Switched Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The APDU9941 offers advanced load management combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management The 0U PDU includes a NEMA L6-30P input plug with 3 05m (10 ft) cord, (21) IEC 60320 C13/C15 and (3) IEC 60320 C19/C21 hybrid outlet receptacles The hybrid outlets allow 60°C operating temperature at full load, are compatible with standard C14 and C20 power cords, and are future-proofed for new C16 and C21 power cords required for higher temperature rated devices The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through Network Management Card and can be accessed, configured, and managed remotely via Web, SNMP and Command Line Interface Color user-interactive LCD interface details current, real power, voltage, and energy measurements for local user access The outlet level control allows power on/off functionality for power recycling/reboot of remote equipment and restricts unauthorized use of individual outlets The Switched Rack PDU includes a temperature/humidity sensor port, locking IEC outlets when used with locking power cords, low-profile circuit breakers and USB port for local Firmware updates The rack PDU supports daisy-chain of up to 32 PDUs on a single IP address, thereby reducing networking cost The rack PDU comes with a standard three-year warranty
AvailabilityNetwork Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkMarketing FeaturesRemote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.AgilitySingle input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
The APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8841 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface. User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access. Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty Enables a quick recovery from overload events and breakers are ultra low profile. Packaging Includes PDU, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable
Add sixteen power outlets to a 19in server rack or cabinetThis 1U Rack Mount Metered PDU features a built-in 8ft (2.4m) NEMA 5-15P power cord and 16x NEMA 5-15R outlets, while the surge protection helps ensure the safe and stable operation of critical equipment. A large backlit LCD provides live readings of electrical parameters for connected devices.Metered Power Distribution UnitMetering is essential for maintaining equipment performance and stability by enabling real-time reads of key electrical parameters: voltage (V), current (Amp), wattage (W), and power factor (PF). The power factor indicates the efficiency of connected devices, with values closer to 1.0 being the most efficient. Monitoring enables early detection of potential issues, efficient load management, and insights for optimizing energy use.The large-font display provides real-time monitoring of key electrical parameters, while the on-demand backlight helps with visibility in dimly lit scenarios.Enhanced Power SafetyThe robust 15A circuit breaker features a mechanical trigger that quickly responds to surges, providing essential protection for the connected. The resettable breaker has a safety cover that prevents unintentional resets. A bright LED indicator confirms active surge protectionRack Mount Design1U horizontal rackmount PDU is compatible with EIA-310-compliant 19-inch 2 or 4-post server racks or cabinets that are 4-inch (10.1cm) or deeperThe TAA-compliant cabinet power strip is constructed from cold-rolled steel that ensures sturdiness and features a textured finish that enhances long-lasting durability. The PDU is equipped with a total of sixteen electrical outlets, including twelve positioned at the rear and four at the front, providing ample connectivity options for various devices in server rooms, data centers, and other professional environments.The StarTech.com Advantage
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.- 120V 15A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 12A continuous)- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord- Digital display continuously reports total output power consumption in amps- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth- 8 built-in NEMA 5-15R outlets- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds- Built-in card slot supports optional SNMPWEBCARD for permanent upgrade to a switched & monitored PDU system- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH15ATAA
The PDUMV30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. LEDs indicate each outlet’s on/off power status. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor each bank’s load in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Distributes Network-Grade Single-Phase Power- 5/5.8kW 208/240V 30A switched PDU with single-phase input/output- Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components- NEMA L6-30P plug with 10 ft. cord connects to compatible AC power source- Firmware upgrades support future product enhancements24 Switched Outlets Distribute AC Power- 20 C13 and 4 C19 outlets split into 2 separately breakered load banks- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices- Plug-lock inserts prevent cables from becoming accidentally disconnectedDigital Ammeter- Reports load level on each bank and total PDU output- Supports IP-address self-ID- Rotates 180° for easy reading at either angleBuilt-In LX Platform Interface- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications CompatibilitySupports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTPSupports automatic and manual assignment of IP addressEasy 0U Installation in EIA-Standard 19 in. Racks- Mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-Compliant- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
APC Basic Rack 1.8kVA. Product color: Black. Input connection type: NEMA 5-15P, Output connections: (10) NEMA 5-15R. Cable length: 144.1" (3.66 m). Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Certification: cUL,CSA,GOST,METI Denan,UL 1363,UL
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA