Description: APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19 Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual Output Voltage(s) (main only) - 120, 208, 230 V Maximum Total Current Draw per Phase - 16 A Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Always on Outlets - 12 Overload Protection Input: Nominal input voltage - 120, 208, 230 Input frequency (Hz) - 50/60 Hz Input Connection Type - IEC-320 C20 Cord Length 8.2 feet ( 2.5 meters ) Acceptable Input Voltage - 90-250 VAC Maximum Line Current per phase - 16.0 A Maximum Input Current per phase - 16.0 A Load Capacity - 3680
Vertiv VP9562. PDU types: Basic, Mounting: Horizontal, Product color: Black. AC outlets quantity: 10 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Nominal input voltage: 100-120 V, Maximum current: 15 A, AC input frequency: 50/60 Hz. Width: 17" (432 mm), Depth: 1.73" (44 mm), Height: 3.74" (95 mm). Package weight: 6 lbs (2.72 kg)
Stay informed about your power with the CyberPower PDU33108 monitored 3-Phase PDU. Ideal for data centers and network closets, this unit provides power monitoring in real time over the network by using the CyberPower management console and the RJ45 Ethernet port for network connection or locally by using the LCD.The PDU33108 supports inputs between 200-240V and includes 42 IEC-320 outlets. Other features include an interactive digital display with selectable background color, high operating temperature range, built-in web interface, and power event notifications. The CyberPower PDU33108 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Remote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Multi-color LCD BackgroundUser selectable background color on digital display allows for easy classification of PDU based on application. The LCD turns red when there is an alert.High Operating Temperature RangeOperates in data center hot aisle up to 140˚F (60˚C).CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging.Switch-Free DesignSafeguards against accidental power shut down.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.Network-Grade Plugs and OutletsHighly-durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Three-Year Limited WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
APC NetShelter Rack PDU Advanced, Switched, 8.6kW, 3PH, 208V, 30A, L21-30P, 48 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA