CyberPower 10-Out 2xNEMA L6-20P
Vertiv VP9562. PDU types: Basic, Mounting: Horizontal, Product color: Black. AC outlets quantity: 10 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Nominal input voltage: 100-120 V, Maximum current: 15 A, AC input frequency: 50/60 Hz. Width: 17" (432 mm), Depth: 1.73" (44 mm), Height: 3.74" (95 mm). Package weight: 6 lbs (2.72 kg)
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.- 120V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord- Visual meter reports output amp and kW power consumption, plus input voltage- 2U horizontal rackmount form factor; 11.9 in. / 30.2 cm depth- 25 outlets (24 5-15/20R, 1 L5-30R)- Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable- Highly reliable solid-state switching enables fast 1-5 millisecond transfer between primary and secondary inputs- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH30ATAA
Managed Universal Input 24 x IEC 60320 C13, 18 x IEC 60320 C39 Network RJ45 0U Vertical Rackmountable Vertical
CyberPower 20A/200V-240V Switched ATS PDU
APC AP9571A. Product color: Gray. Input connection type: NEMA L6-30P. Cable length: 144.1" (3.66 m). AC input frequency: 60 Hz, Nominal output voltage: 208 V, Maximum total current draw per phase: 24 A. Width: 17.5" (445 mm), Depth: 3.03" (77 mm), Dimensions (WxDxH): 17.5 x 3.03 x 1.73" (445 x 77 x 44 mm)
Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution. Supplies equipment with continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- PDUV20 offers highly reliable 20A 120V power distribution in a 36 in. / .9m 0U vertical rackmount format (Agency de-rated to 16A continuous)- 14 NEMA 5-15/20R output receptacles- NEMA L5-20P input plug and 5-20P adapter- 15 ft. / 4.6m attached line cord- 20A resettable circuit breaker- Switch-free design prevents accidental shutoff- Toolless mounting buttons enable simple installation in Tripp Lite and other button-mount compatible equipment racks- Rear facing installation buttons can be relocated to the left or right surface of the PDU for rear, center or forward-facing outlet orientation in compatible racks- Included nut and bolt mounting brackets support installation in non button-mount compatible racks, wallmount and raceway applications
Description - APC Basic Rack PDU, Input : 208, 230V , Input Connection Type : IEC-320 C14 , Cord Length : 6.5 feet ( 1.98 meters ) , Output : 208, 230V , Output Connections : (15)IEC 320 C13 Features - Low Cost Power Distribution, Toolless Mounting Capabilities, Vertical Mounting Capabilities Includes - Installation Guide, Rack Mounting Brackets, Toolless Mounting Kit Output: Output Voltage(s) (main only) - 208, 230 V Maximum Total Current Draw per Phase - 10 A Output Connections - (15)IEC 320 C13 Input: Nominal input voltage - 208, 230 Input frequency (Hz) - 50/60 Hz Input Connection Type - IEC-320 C14 Cord Length - 6.5 feet ( 1.98 meters ) Acceptable Input Voltage - 200-240 VAC Maximum Input Current per phase - 10.0 A Load Capacity - 2300
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA