3Phase Basic PDU, 50A/200V240V, 0U, 30 IEC320 C13 + 6 IEC320 C19, Hubbell CS8365C
Ensure continued operation of critical devices with the CyberPower PDU44001 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.The PDU44001 supports inputs between 100-120V and includes (10) NEMA 5-15R outlets. Dual NEMA 5-15P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44001 is protected by a three-year limited warranty.
Description: APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19 Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual Output Voltage(s) (main only) - 120, 208, 230 V Maximum Total Current Draw per Phase - 16 A Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Always on Outlets - 12 Overload Protection Input: Nominal input voltage - 120, 208, 230 Input frequency (Hz) - 50/60 Hz Input Connection Type - IEC-320 C20 Cord Length 8.2 feet ( 2.5 meters ) Acceptable Input Voltage - 90-250 VAC Maximum Line Current per phase - 16.0 A Maximum Input Current per phase - 16.0 A Load Capacity - 3680
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 8.6kW, 3PH, 208V 30A, L21-30P, 48 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Tripp Lite PDUMNV15LX. PDU types: Monitored, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 16 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 1–15P. Cable length: 118.1" (3 m). Monitoring: Current, Supported network protocols: HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 100; 120; 127 V, Maximum current: 12 A, AC input frequency: 50 / 60 Hz
AP7998BFeaturesRACK PDU,SWITCHED,ZEROU,12.5KW,208V,(21)C13&(3)C19;10 CORDSwitched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.Includes : Cord Retention Bracket(s) , Documentation CD , Installation Guide , Rack Mounting Brackets , RS-232 configuration cable , Toolless Mounting KitLocal and web-based monitoringStatus available to customers both in the data center and remotelyResettable circuit breakersEnables a quick recovery from overload events.Toolless Rack Mounting CapabilitiesServer cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.Vertical Mounting CapabilitiesEasily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.AgilitySingle input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Marketing FeaturesLocal Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).AvailabilityAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkNetwork Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
CyberPower PDU24004 provides output from a UPS unit, generator, or utility power to multiple connected devices in IT environments. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If the selected power source exceeds the desired thresholds or fails, the ATS PDU will automatically switch to the other power source to ensure continuous operation.The unit comes with a hot-swappable multifunction readout that displays real-time vitals including current, input voltage, power consumption levels in amps and watts. The digital LCD display is also color configurable, allowing easy maintenance and monitoring of the ATS PDU. Users can change LCD’s colors to easily categorize devices between multiple machines in server room and IT environments. The firmware can also be conveniently upgraded via the USB port, ensuring the latest features and updates are available for users.
Stay informed about your power with the CyberPower PDU33108 monitored 3-Phase PDU. Ideal for data centers and network closets, this unit provides power monitoring in real time over the network by using the CyberPower management console and the RJ45 Ethernet port for network connection or locally by using the LCD.The PDU33108 supports inputs between 200-240V and includes 42 IEC-320 outlets. Other features include an interactive digital display with selectable background color, high operating temperature range, built-in web interface, and power event notifications. The CyberPower PDU33108 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Remote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Multi-color LCD BackgroundUser selectable background color on digital display allows for easy classification of PDU based on application. The LCD turns red when there is an alert.High Operating Temperature RangeOperates in data center hot aisle up to 140˚F (60˚C).CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging.Switch-Free DesignSafeguards against accidental power shut down.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.Network-Grade Plugs and OutletsHighly-durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Three-Year Limited WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.